Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Louisiana, Lafayette |
---|---|
Assessment Year | 2002 |
Principal Product | Newspapers |
NAICS | n/a |
SIC | 2711 - Newspapers |
Sales | $5,000,000-$10,000,000 |
# of Employees | 60 |
Plant Area (Sq.Ft.) | 48,000 |
Annual Production | 50,000,000 Pieces |
Production Hrs. Annual | 8,736 |
Location (State) | LA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $151,177 | 2,971,360 | kWh | $0.05 |
Electricity Demand | $36,336 | 7,267 | kW-months/year | $5.00 |
Electricity Fees | $7,501 | - | $ | - |
Natural Gas | $2,580 | 2,617 | MMBtu | $0.99 |
TOTAL ENERGY COSTS | $209,276 | |||
RECOMMENDED SAVINGS* | $31,009 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $11,239 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Solid Waste (non-haz) | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Electricity Fees | Solid Waste (non-haz) | One-time Revenue or Avoided Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | lb | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $10,620 Cost: $15,435 |
- | - | $10,212 | 1,817 | $408 | - | - | - | - | - |
- - kWh |
$10,212 1,817 kW-months/year |
$408 - $ |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS |
Savings: $5,546 Cost: - |
$4,864 | 95,607 | $469 | 94 | $213 | - | - | - | - | - |
$4,864 95,607 kWh |
$469 94 kW-months/year |
$213 - $ |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $3,800 Cost: $1,080 |
$3,654 | 71,818 | - | - | $146 | - | - | - | - | - |
$3,654 71,818 kWh |
- - kW-months/year |
$146 - $ |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS |
Savings: $2,311 Cost: - |
$2,027 | 39,836 | $195 | 39 | $89 | - | - | - | - | - |
$2,027 39,836 kWh |
$195 39 kW-months/year |
$89 - $ |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7243 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS |
Savings: $2,079 Cost: $2,307 |
$1,999 | 39,281 | - | - | $80 | - | - | - | - | - |
$1,999 39,281 kWh |
- - kW-months/year |
$80 - $ |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7134 USE PHOTOCELL CONTROLS |
Savings: $1,293 Cost: $260 |
$1,163 | 22,854 | $80 | 16 | $50 | - | - | - | - | - |
$1,163 22,854 kWh |
$80 16 kW-months/year |
$50 - $ |
- - lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 4.611 BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE |
Savings: $1,505 Cost: $2,255 |
- | - | - | - | - | - | - | - | $1,505 | - |
- - kWh |
- - kW-months/year |
- - $ |
- - lb |
$1,505 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 3.5313 INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE |
Savings: $3,855 Cost: - |
- | - | - | - | - | - | $3,855 | 1,140 | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$3,855 1,140 lb |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $31,009 Cost: $21,337 |
$13,707 | 269,396 | $10,956 | 1,966 | $986 | - | $3,855 | 1,140 | $1,505 | - | $13,707 269,396 kWh |
$10,956 1,966 kW-months/year |
$986 - $ |
$3,855 1,140 lb |
$1,505 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $11,239 Cost: $5,642 |
$5,653 | 111,099 | - | - | $226 | - | $3,855 | 1,140 | $1,505 | - | $5,653 111,099 kWh |
- - kW-months/year |
$226 - $ |
$3,855 1,140 lb |
$1,505 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | lb | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Solid Waste (non-haz) | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Electricity Fees | Solid Waste (non-haz) | One-time Revenue or Avoided Cost |