Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Louisiana, Lafayette |
---|---|
Assessment Year | 2002 |
Principal Product | Plastic dinnerware |
NAICS | n/a |
SIC | 3089 - Plastics Products, Nec |
Sales | $100,000,000-$500,000,000 |
# of Employees | 250 |
Plant Area (Sq.Ft.) | 143,523 |
Annual Production | 600,000 Units |
Production Hrs. Annual | 8,736 |
Location (State) | LA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $429,213 | 13,568,600 | kWh | $0.03 |
Electricity Demand | $121,358 | 22,065 | kW-months/year | $5.50 |
Electricity Fees | $22,023 | - | $ | - |
TOTAL ENERGY COSTS | $572,594 | |||
RECOMMENDED SAVINGS* | $18,193 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $13,920 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Electricity Fees | One-time Revenue or Avoided Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $6,310 Cost: $10,850 |
- | - | $6,067 | 1,103 | $243 | - | - | - |
- - kWh |
$6,067 1,103 kW-months/year |
$243 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $5,890 Cost: $2,580 |
$5,663 | 179,045 | - | - | $227 | - | - | - |
$5,663 179,045 kWh |
- - kW-months/year |
$227 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS |
Savings: $2,680 Cost: - |
$2,038 | 64,428 | $539 | 98 | $103 | - | - | - |
$2,038 64,428 kWh |
$539 98 kW-months/year |
$103 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS |
Savings: $1,286 Cost: - |
$978 | 30,925 | $259 | 47 | $49 | - | - | - |
$978 30,925 kWh |
$259 47 kW-months/year |
$49 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7134 USE PHOTOCELL CONTROLS |
Savings: $205 Cost: $52 |
$109 | 3,436 | $88 | 16 | $8 | - | - | - |
$109 3,436 kWh |
$88 16 kW-months/year |
$8 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7134 USE PHOTOCELL CONTROLS |
Savings: $102 Cost: $41 |
$54 | 1,718 | $44 | 8 | $4 | - | - | - |
$54 1,718 kWh |
$44 8 kW-months/year |
$4 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 4.611 BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE |
Savings: $1,720 Cost: $2,400 |
- | - | - | - | - | - | $1,720 | - |
- - kWh |
- - kW-months/year |
- - $ |
$1,720 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $18,193 Cost: $15,923 |
$8,842 | 279,552 | $6,997 | 1,272 | $634 | - | $1,720 | - | $8,842 279,552 kWh |
$6,997 1,272 kW-months/year |
$634 - $ |
$1,720 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $13,920 Cost: $15,830 |
$5,663 | 179,045 | $6,067 | 1,103 | $470 | - | $1,720 | - | $5,663 179,045 kWh |
$6,067 1,103 kW-months/year |
$470 - $ |
$1,720 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Electricity Fees | One-time Revenue or Avoided Cost |