Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Louisiana, Lafayette
Assessment Year 2002
Principal Product Fire Trucks
NAICS n/a
SIC 3711 - Motor Vehicles And Car Bodies
Sales $50,000,000-$100,000,000
# of Employees 300
Plant Area (Sq.Ft.) 150,000
Annual Production 250 Pieces
Production Hrs. Annual 4,602
Location (State) LA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $54,710 2,274,750 kWh $0.02
Electricity Demand $44,572 7,189 kW-months/year $6.20
Electricity Fees $8,643 - $ -
Natural Gas $35,997 3,190 MMBtu $11.28
TOTAL ENERGY COSTS $143,922
RECOMMENDED SAVINGS* $16,870 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $3,671
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Electricity Fees Electricity Usage Electricity Demand Electricity Fees
$ kWh $ kW-months/year $ $
01: 2.3212 OPTIMIZE PLANT POWER FACTOR Savings:
$6,951
Cost:
$9,520
- - $6,684 1,078 $267 - -
-
kWh
$6,684
1,078
kW-months/year
$267
-
$
02: 2.7134 USE PHOTOCELL CONTROLS Savings:
$3,964
Cost:
$416
$2,491 103,574 $1,321 213 $152 - $2,491
103,574
kWh
$1,321
213
kW-months/year
$152
-
$
03: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS Savings:
$3,671
Cost:
-
$1,918 79,743 $1,612 260 $141 - $1,918
79,743
kWh
$1,612
260
kW-months/year
$141
-
$
04: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$762
Cost:
$78
$479 19,918 $254 41 $29 - $479
19,918
kWh
$254
41
kW-months/year
$29
-
$
05: 2.7134 USE PHOTOCELL CONTROLS Savings:
$460
Cost:
$52
$287 11,951 $155 25 $18 - $287
11,951
kWh
$155
25
kW-months/year
$18
-
$
06: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$312
Cost:
$52
$195 8,126 $105 17 $12 - $195
8,126
kWh
$105
17
kW-months/year
$12
-
$
07: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$200
Cost:
$260
$87 3,628 $105 17 $8 - $87
3,628
kWh
$105
17
kW-months/year
$8
-
$
08: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$198
Cost:
$52
$122 5,079 $68 11 $8 - $122
5,079
kWh
$68
11
kW-months/year
$8
-
$
09: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$198
Cost:
$52
$122 5,079 $68 11 $8 - $122
5,079
kWh
$68
11
kW-months/year
$8
-
$
10: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$154
Cost:
$52
$98 4,063 $50 8 $6 - $98
4,063
kWh
$50
8
kW-months/year
$6
-
$
TOTAL RECOMMENDED Savings:
$16,870
Cost:
$10,534
$5,799 241,161 $10,422 1,681 $649 - $5,799
241,161
kWh
$10,422
1,681
kW-months/year
$649
-
$
TOTAL IMPLEMENTED Savings:
$3,671
Cost:
-
$1,918 79,743 $1,612 260 $141 - $1,918
79,743
kWh
$1,612
260
kW-months/year
$141
-
$
Savings
Cost
$ kWh $ kW-months/year $ $
Electricity Usage Electricity Demand Electricity Fees Electricity Usage Electricity Demand Electricity Fees