IAC logo
IAC Assessment: LL0151
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: LL0151
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Louisiana, Lafayette
Assessment Year 2003
Principal Product Oilfiled Tools
NAICS n/a
SIC 3533 - Oil And Gas Field Machinery
Sales $50,000,000-$100,000,000
# of Employees 240
Plant Area (Sq.Ft.) 180,000
Annual Production 6,000 Pieces
Production Hrs. Annual 8,736
Location (State) LA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $164,912 4,499,348 kWh $0.04
Electricity Demand $71,618 9,744 kW-months/year $7.35
Electricity Fees $935 - $ -
Natural Gas $169,532 31,300 MMBtu $5.42
TOTAL ENERGY COSTS $450,197
RECOMMENDED SAVINGS* $101,502 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $70,544
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Electricity Fees Natural Gas Other Liquid (haz) Administrative Changes Electricity Usage Electricity Demand Electricity Fees Natural Gas Other Liquid (haz) Administrative Changes
$ kWh $ kW-months/year $ $ $ MMBtu $ gal $ $
01: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$15,605
Cost:
$4,350
$15,005 412,688 - - $600 - - - - - - - $15,005
412,688
kWh
-
-
kW-months/year
$600
-
$
-
-
MMBtu
-
-
gal
-
-
$
02: 2.7243 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS Savings:
$15,140
Cost:
$4,600
- - - - - - $15,140 2,656 - - - - -
-
kWh
-
-
kW-months/year
-
-
$
$15,140
2,656
MMBtu
-
-
gal
-
-
$
03: 2.7134 USE PHOTOCELL CONTROLS Savings:
$10,108
Cost:
$1,092
$5,456 150,050 $4,263 580 $389 - - - - - - - $5,456
150,050
kWh
$4,263
580
kW-months/year
$389
-
$
-
-
MMBtu
-
-
gal
-
-
$
04: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$5,710
Cost:
$494
$4,299 118,223 $1,191 162 $220 - - - - - - - $4,299
118,223
kWh
$1,191
162
kW-months/year
$220
-
$
-
-
MMBtu
-
-
gal
-
-
$
05: 2.1134 ELIMINATE LEAKS IN COMBUSTIBLE GAS LINES Savings:
$3,410
Cost:
$1,240
- - - - - - $3,410 600 - - - - -
-
kWh
-
-
kW-months/year
-
-
$
$3,410
600
MMBtu
-
-
gal
-
-
$
06: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS Savings:
$1,284
Cost:
$180
$869 23,902 $366 50 $49 - - - - - - - $869
23,902
kWh
$366
50
kW-months/year
$49
-
$
-
-
MMBtu
-
-
gal
-
-
$
07: 3.5111 FILTER AND REUSE HYDRAULIC OIL Savings:
$40,689
Cost:
$8,000
- - - - - - - - $40,689 91,200 - - -
-
kWh
-
-
kW-months/year
-
-
$
-
-
MMBtu
$40,689
91,200
gal
-
-
$
08: 4.611 BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE Savings:
$9,556
Cost:
$12,425
- - - - - - - - - - $9,556 - -
-
kWh
-
-
kW-months/year
-
-
$
-
-
MMBtu
-
-
gal
$9,556
-
$
TOTAL RECOMMENDED Savings:
$101,502
Cost:
$32,381
$25,629 704,863 $5,820 792 $1,258 - $18,550 3,256 $40,689 91,200 $9,556 - $25,629
704,863
kWh
$5,820
792
kW-months/year
$1,258
-
$
$18,550
3,256
MMBtu
$40,689
91,200
gal
$9,556
-
$
TOTAL IMPLEMENTED Savings:
$70,544
Cost:
$26,195
$15,874 436,590 $366 50 $649 - $3,410 600 $40,689 91,200 $9,556 - $15,874
436,590
kWh
$366
50
kW-months/year
$649
-
$
$3,410
600
MMBtu
$40,689
91,200
gal
$9,556
-
$
Savings
Cost
$ kWh $ kW-months/year $ $ $ MMBtu $ gal $ $
Electricity Usage Electricity Demand Electricity Fees Natural Gas Other Liquid (haz) Administrative Changes Electricity Usage Electricity Demand Electricity Fees Natural Gas Other Liquid (haz) Administrative Changes