Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Louisiana, Lafayette |
---|---|
Assessment Year | 2007 |
Principal Product | Flow meeters |
NAICS | 334513 - Instruments and Related Products Manufacturing for Measuring, Displaying, and Controlling Industrial |
SIC | 3823 - Process Control Instruments |
Sales | $100,000,000-$500,000,000 |
# of Employees | 30 |
Plant Area (Sq.Ft.) | 14,000 |
Annual Production | 1,000 Pieces |
Production Hrs. Annual | 2,375 |
Location (State) | LA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $32,612 | 338,123 | kWh | $0.10 |
Electricity Demand | $4,747 | 1,579 | kW-months/year | $3.01 |
Electricity Fees | $1,233 | - | $ | - |
Natural Gas | $1,508 | 84 | MMBtu | $17.95 |
TOTAL ENERGY COSTS | $40,100 | |||
RECOMMENDED SAVINGS* | $7,332 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $6,032 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Fees | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Fees | One-time Revenue or Avoided Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 4.611 BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE |
Savings: $3,109 Cost: $60 |
$1,558 | 16,150 | $51 | - | $1,500 | - |
$1,558 16,150 kWh |
$51 - $ |
$1,500 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4238 DO NOT USE COMPRESSED AIR FOR PERSONAL COOLING |
Savings: $1,914 Cost: $1,160 |
$1,853 | 19,208 | $61 | - | - | - |
$1,853 19,208 kWh |
$61 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $1,056 Cost: $900 |
$1,022 | 10,596 | $34 | - | - | - |
$1,022 10,596 kWh |
$34 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS |
Savings: $603 Cost: $252 |
$584 | 6,060 | $19 | - | - | - |
$584 6,060 kWh |
$19 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7224 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS |
Savings: $291 Cost: $330 |
$282 | 2,923 | $9 | - | - | - |
$282 2,923 kWh |
$9 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $145 Cost: $1,734 |
$140 | 1,455 | $5 | - | - | - |
$140 1,455 kWh |
$5 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.6211 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES |
Savings: $115 Cost: $319 |
$111 | 1,150 | $4 | - | - | - |
$111 1,150 kWh |
$4 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $99 Cost: $81 |
$96 | 994 | $3 | - | - | - |
$96 994 kWh |
$3 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $7,332 Cost: $4,836 |
$5,646 | 58,536 | $186 | - | $1,500 | - | $5,646 58,536 kWh |
$186 - $ |
$1,500 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $6,032 Cost: $2,121 |
$4,388 | 45,491 | $144 | - | $1,500 | - | $4,388 45,491 kWh |
$144 - $ |
$1,500 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Fees | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Fees | One-time Revenue or Avoided Cost |