Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Louisiana, Lafayette
Assessment Year 2010
Principal Product Research
NAICS 211111 - Crude Petroleum and Natural Gas Extraction
SIC 1311 - Crude Petroleum And Natural Gas
Sales <$500,000
# of Employees 20
Plant Area (Sq.Ft.) 70,000
Annual Production 0 Units
Production Hrs. Annual 8,736
Location (State) LA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $413,449 6,856,800 kWh $0.06
TOTAL ENERGY COSTS $413,449
RECOMMENDED SAVINGS* $417,262 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $307
#|Description Savings
Cost
Status Electricity Usage One-time Revenue or Avoided Cost Electricity Usage One-time Revenue or Avoided Cost
$ kWh $ $
01: 2.7224 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS Savings:
$126,427
Cost:
$900
$126,427 2,096,640 - - $126,427
2,096,640
kWh
-
-
$
02: 2.9131 INSTALL HYDROGEN FUEL CELL Savings:
$112,994
Cost:
$400,000
$112,994 1,873,872 - - $112,994
1,873,872
kWh
-
-
$
03: 2.7226 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE Savings:
$82,693
Cost:
$100,000
$82,693 1,371,360 - - $82,693
1,371,360
kWh
-
-
$
04: 2.6212 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME Savings:
$81,713
Cost:
$1,560
$81,713 1,355,113 - - $81,713
1,355,113
kWh
-
-
$
05: 2.7124 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED Savings:
$8,816
Cost:
$597
$8,816 146,206 - - $8,816
146,206
kWh
-
-
$
06: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS Savings:
$1,771
Cost:
$850
$1,771 29,374 - - $1,771
29,374
kWh
-
-
$
07: 4.611 BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE Savings:
$1,715
Cost:
$240
$215 3,562 $1,500 - $215
3,562
kWh
$1,500
-
$
08: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$615
Cost:
$690
$615 10,203 - - $615
10,203
kWh
-
-
$
09: 2.7134 USE PHOTOCELL CONTROLS Savings:
$307
Cost:
$30
$307 5,097 - - $307
5,097
kWh
-
-
$
10: 2.6211 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES Savings:
$211
Cost:
$312
$211 3,494 - - $211
3,494
kWh
-
-
$
TOTAL RECOMMENDED Savings:
$417,262
Cost:
$505,179
$415,762 6,894,921 $1,500 - $415,762
6,894,921
kWh
$1,500
-
$
TOTAL IMPLEMENTED Savings:
$307
Cost:
$30
$307 5,097 - - $307
5,097
kWh
-
-
$
Savings
Cost
$ kWh $ $
Electricity Usage One-time Revenue or Avoided Cost Electricity Usage One-time Revenue or Avoided Cost