Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Loyola Marymount University |
---|---|
Assessment Year | 2003 |
Principal Product | knitted, dyed and printed fabrics |
NAICS | 335931 - Current-Carrying Wiring Device Manufacturing |
SIC | 2211 - Broadwoven Fabric Mills, Cotton |
Sales | $10,000,000-$50,000,000 |
# of Employees | 250 |
Plant Area (Sq.Ft.) | 150,000 |
Annual Production | 22,072,309 Pounds |
Production Hrs. Annual | 5,000 |
Location (State) | CA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $541,949 | 11,333,467 | kWh | $0.05 |
Electricity Demand | $245,797 | 26,184 | kW-months/year | $9.39 |
Electricity Fees | $11,605 | - | $ | - |
Natural Gas | $980,672 | 270,905 | MMBtu | $3.62 |
TOTAL ENERGY COSTS | $1,780,023 | |||
RECOMMENDED SAVINGS* | $50,237 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $18,225 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7131 ADD AREA LIGHTING SWITCHES |
Savings: $6,786 Cost: $7,274 |
$5,764 | 119,197 | $1,022 | 214 | - | - | - | - |
$5,764 119,197 kWh |
$1,022 214 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $5,174 Cost: $250 |
$4,811 | 99,850 | $1,143 | 20 | - | - | $(-780) | - |
$4,811 99,850 kWh |
$1,143 20 kW-months/year |
- - MMBtu |
$(-780) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT |
Savings: $12,012 Cost: $18,500 |
- | - | - | - | $12,012 | 2,755 | - | - |
- - kWh |
- - kW-months/year |
$12,012 2,755 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $6,265 Cost: $2,028 |
- | - | - | - | $6,265 | 1,437 | - | - |
- - kWh |
- - kW-months/year |
$6,265 1,437 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 4.122 DEVELOP STANDARD PROCEDURES TO IMPROVE INTERNAL YIELDS |
Savings: $20,000 Cost: $19,260 |
- | - | - | - | - | - | $20,000 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$20,000 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $50,237 Cost: $47,312 |
$10,575 | 219,047 | $2,165 | 234 | $18,277 | 4,192 | $19,220 | - | $10,575 219,047 kWh |
$2,165 234 kW-months/year |
$18,277 4,192 MMBtu |
$19,220 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $18,225 Cost: $9,552 |
$10,575 | 219,047 | $2,165 | 234 | $6,265 | 1,437 | $(-780) | - | $10,575 219,047 kWh |
$2,165 234 kW-months/year |
$6,265 1,437 MMBtu |
$(-780) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes |