Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Loyola Marymount University |
---|---|
Assessment Year | 2006 |
Principal Product | frozen meals |
NAICS | 311412 - Frozen Specialty Food Manufacturing |
SIC | 2038 - Frozen Specialties, Nec |
Sales | $10,000,000-$50,000,000 |
# of Employees | 220 |
Plant Area (Sq.Ft.) | 51,000 |
Annual Production | 600 Tons |
Production Hrs. Annual | 4,572 |
Location (State) | CA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $167,133 | 2,479,037 | kWh | $0.07 |
Electricity Demand | $98,347 | 6,008 | kW-months/year | $16.37 |
Electricity Fees | $31,395 | - | $ | - |
Natural Gas | $31,033 | 3,564 | MMBtu | $8.71 |
TOTAL ENERGY COSTS | $327,908 | |||
RECOMMENDED SAVINGS* | $539,758 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $487,776 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Personnel Changes | Administrative Changes | Electricity Usage | Electricity Demand | Personnel Changes | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7425 CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD |
Savings: $42,160 Cost: $64,000 |
$18,883 | 259,811 | $23,277 | 1,452 | - | - | - | - |
$18,883 259,811 kWh |
$23,277 1,452 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4224 UPGRADE CONTROLS ON COMPRESSORS |
Savings: $9,822 Cost: - |
- | - | $9,822 | 600 | - | - | - | - |
- - kWh |
$9,822 600 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 4.432 CROSS-TRAIN PERSONNEL TO AVOID LOST TIME |
Savings: $287,197 Cost: - |
$37,597 | 495,807 | - | - | $249,600 | - | - | - |
$37,597 495,807 kWh |
- - kW-months/year |
$249,600 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 4.311 SCHEDULE DELIVERIES ACCORDING TO DEMAND |
Savings: $16,460 Cost: - |
$2,657 | 35,040 | $7,858 | 480 | - | - | $5,945 | - |
$2,657 35,040 kWh |
$7,858 480 kW-months/year |
- - $ |
$5,945 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 4.432 CROSS-TRAIN PERSONNEL TO AVOID LOST TIME |
Savings: $184,119 Cost: $15,120 |
$9,399 | 123,952 | - | - | $174,720 | - | - | - |
$9,399 123,952 kWh |
- - kW-months/year |
$174,720 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $539,758 Cost: $79,120 |
$68,536 | 914,610 | $40,957 | 2,532 | $424,320 | - | $5,945 | - | $68,536 914,610 kWh |
$40,957 2,532 kW-months/year |
$424,320 - $ |
$5,945 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $487,776 Cost: $15,120 |
$49,653 | 654,799 | $7,858 | 480 | $424,320 | - | $5,945 | - | $49,653 654,799 kWh |
$7,858 480 kW-months/year |
$424,320 - $ |
$5,945 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Personnel Changes | Administrative Changes | Electricity Usage | Electricity Demand | Personnel Changes | Administrative Changes |