Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Louisiana State University
Assessment Year 2024
Principal Product Industrial Laundry Service
NAICS 812332 - Industrial Launderers
SIC 7218 - Industrial Launderers
Sales $10,000,000-$50,000,000
# of Employees 185
Plant Area (Sq.Ft.) 168,000
Annual Production 17,160,000 Pounds
Production Hrs. Annual 6,240
Location (State) LA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $126,561 1,461,888 kWh $0.09
Electricity Demand $14,787 3,589 kW-months/year $4.12
Natural Gas $106,431 12,472 MMBtu $8.53
TOTAL ENERGY COSTS $247,779
RECOMMENDED SAVINGS* $248,542 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $180,540
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Primary Product Electricity Usage Electricity Demand Natural Gas Primary Product
$ kWh $ kW-months/year $ MMBtu $ $
01: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED Savings:
$1,796
Cost:
$25
$1,796 20,640 - - - - - - $1,796
20,640
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
02: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS Savings:
$1,962
Cost:
$75
$1,962 22,549 - - - - - - $1,962
22,549
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
03: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT Savings:
$17,495
Cost:
$20,000
- - - - $17,495 2,050 - - -
-
kWh
-
-
kW-months/year
$17,495
2,050
MMBtu
-
-
$
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$1,104
Cost:
$1,413
$1,013 11,644 $91 22 - - - - $1,013
11,644
kWh
$91
22
kW-months/year
-
-
MMBtu
-
-
$
05: 4.111 ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK Savings:
$175,678
Cost:
$600,000
$(-18,419) (-211,719) - - - - $194,097 - $(-18,419)
(-211,719)
kWh
-
-
kW-months/year
-
-
MMBtu
$194,097
-
$
06: 2.7232 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL Savings:
$12,486
Cost:
$113,400
$12,486 143,520 - - - - - - $12,486
143,520
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
07: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY Savings:
$38,021
Cost:
$514,800
$38,021 437,019 - - - - - - $38,021
437,019
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
TOTAL RECOMMENDED Savings:
$248,542
Cost:
$1,249,713
$36,859 423,653 $91 22 $17,495 2,050 $194,097 - $36,859
423,653
kWh
$91
22
kW-months/year
$17,495
2,050
MMBtu
$194,097
-
$
TOTAL IMPLEMENTED Savings:
$180,540
Cost:
$601,513
$(-13,648) (-156,886) $91 22 - - $194,097 - $(-13,648)
(-156,886)
kWh
$91
22
kW-months/year
-
-
MMBtu
$194,097
-
$
Savings
Cost
$ kWh $ kW-months/year $ MMBtu $ $
Electricity Usage Electricity Demand Natural Gas Primary Product Electricity Usage Electricity Demand Natural Gas Primary Product