Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Louisiana State University |
---|---|
Assessment Year | 2024 |
Principal Product | Industrial Laundry Service |
NAICS | 812332 - Industrial Launderers |
SIC | 7218 - Industrial Launderers |
Sales | $10,000,000-$50,000,000 |
# of Employees | 185 |
Plant Area (Sq.Ft.) | 168,000 |
Annual Production | 17,160,000 Pounds |
Production Hrs. Annual | 6,240 |
Location (State) | LA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $126,561 | 1,461,888 | kWh | $0.09 |
Electricity Demand | $14,787 | 3,589 | kW-months/year | $4.12 |
Natural Gas | $106,431 | 12,472 | MMBtu | $8.53 |
TOTAL ENERGY COSTS | $247,779 | |||
RECOMMENDED SAVINGS* | $248,542 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $180,540 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Primary Product | Electricity Usage | Electricity Demand | Natural Gas | Primary Product | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $1,796 Cost: $25 |
$1,796 | 20,640 | - | - | - | - | - | - |
$1,796 20,640 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS |
Savings: $1,962 Cost: $75 |
$1,962 | 22,549 | - | - | - | - | - | - |
$1,962 22,549 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $17,495 Cost: $20,000 |
- | - | - | - | $17,495 | 2,050 | - | - |
- - kWh |
- - kW-months/year |
$17,495 2,050 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $1,104 Cost: $1,413 |
$1,013 | 11,644 | $91 | 22 | - | - | - | - |
$1,013 11,644 kWh |
$91 22 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 4.111 ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK |
Savings: $175,678 Cost: $600,000 |
$(-18,419) | (-211,719) | - | - | - | - | $194,097 | - |
$(-18,419) (-211,719) kWh |
- - kW-months/year |
- - MMBtu |
$194,097 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7232 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL |
Savings: $12,486 Cost: $113,400 |
$12,486 | 143,520 | - | - | - | - | - | - |
$12,486 143,520 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY |
Savings: $38,021 Cost: $514,800 |
$38,021 | 437,019 | - | - | - | - | - | - |
$38,021 437,019 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $248,542 Cost: $1,249,713 |
$36,859 | 423,653 | $91 | 22 | $17,495 | 2,050 | $194,097 | - | $36,859 423,653 kWh |
$91 22 kW-months/year |
$17,495 2,050 MMBtu |
$194,097 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $180,540 Cost: $601,513 |
$(-13,648) | (-156,886) | $91 | 22 | - | - | $194,097 | - | $(-13,648) (-156,886) kWh |
$91 22 kW-months/year |
- - MMBtu |
$194,097 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Primary Product | Electricity Usage | Electricity Demand | Natural Gas | Primary Product |