IAC logo
IAC Assessment: LS1022
Sponsored by:
EERE AMO
IAC logo
IAC Assessment: LS1022
IAC Center Louisiana State University
Assessment Year 2022
Principal Product Petroleum Bulk Stations and Terminals
NAICS 424710 - Petroleum Bulk Stations and Terminals
SIC 5171 - Petroleum Bulk Stations & Terminals
Sales <$500,000
# of Employees 30
Plant Area (Sq.Ft.) 973,000
Annual Production 1 Units
Production Hrs. Annual 8,760
Location (State) LA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $120,924 1,540,600 kWh $0.08
Electricity Demand $23,299 5,652 kW-months/year $4.12
Natural Gas $356,621 71,882 MMBtu $4.96
TOTAL ENERGY COSTS $500,844
RECOMMENDED SAVINGS* $373,372 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Personnel Changes Administrative Changes Electricity Usage Electricity Demand Natural Gas Personnel Changes Administrative Changes
$ kWh $ kW-months/year $ MMBtu $ $ $ $
01: 4.661 LEVEL ZERO – INSTALL CONTROL SYSTEMS FOR EXISTING EQUIPMENT Savings:
$1,456
Cost:
-
- - - - - - $1,456 - - - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
$1,456
-
$
-
-
$
02: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS Savings:
$1,565
Cost:
$88
$1,565 19,937 - - - - - - - - $1,565
19,937
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
-
-
$
03: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$2,360
Cost:
$270
$2,360 30,064 - - - - - - - - $2,360
30,064
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
-
-
$
04: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$248
Cost:
$50
$248 3,154 - - - - - - - - $248
3,154
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
-
-
$
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$22,202
Cost:
$12,065
$19,749 251,610 $2,453 595 - - - - - - $19,749
251,610
kWh
$2,453
595
kW-months/year
-
-
MMBtu
-
-
$
-
-
$
06: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$71,544
Cost:
$66,750
$71,544 911,481 - - - - - - - - $71,544
911,481
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
-
-
$
07: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT Savings:
$84,344
Cost:
$218,400
- - - - $84,344 17,001 - - - - -
-
kWh
-
-
kW-months/year
$84,344
17,001
MMBtu
-
-
$
-
-
$
08: 2.1224 REPLACE BOILER Savings:
$186,054
Cost:
$504,000
- - - - $186,054 37,502 - - - - -
-
kWh
-
-
kW-months/year
$186,054
37,502
MMBtu
-
-
$
-
-
$
09: 3.1291 ELIMINATE PRACTICE OF MIXING WASTE STREAMS Savings:
$3,599
Cost:
$16,545
- - - - - - - - $3,599 - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
$3,599
-
$
TOTAL RECOMMENDED Savings:
$373,372
Cost:
$818,168
$95,466 1,216,246 $2,453 595 $270,398 54,503 $1,456 - $3,599 - $95,466
1,216,246
kWh
$2,453
595
kW-months/year
$270,398
54,503
MMBtu
$1,456
-
$
$3,599
-
$
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - - - - - - - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
-
-
$
Savings
Cost
$ kWh $ kW-months/year $ MMBtu $ $ $ $
Electricity Usage Electricity Demand Natural Gas Personnel Changes Administrative Changes Electricity Usage Electricity Demand Natural Gas Personnel Changes Administrative Changes