IAC logo
IAC Assessment: LS1923
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: LS1923
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Louisiana State University
Assessment Year 2023
Principal Product Individual And Family Services
NAICS 624110 - Child and Youth Services
SIC 8322 - Individual And Family Services
Sales <$500,000
# of Employees 100
Plant Area (Sq.Ft.) 392,040
Annual Production 1 Units
Production Hrs. Annual 2,860
Location (State) LA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $78,966 765,272 kWh $0.10
Electricity Demand $6,790 1,648 kW-months/year $4.12
Natural Gas $5,702 384 MMBtu $14.85
TOTAL ENERGY COSTS $91,458
RECOMMENDED SAVINGS* $49,925 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas
$ kWh $ kW-months/year $ MMBtu
01: 2.7211 CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS Savings:
$3,175
Cost:
$750
$3,175 30,825 - - - - $3,175
30,825
kWh
-
-
kW-months/year
-
-
MMBtu
02: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$8,272
Cost:
$1,300
$8,272 80,309 - - - - $8,272
80,309
kWh
-
-
kW-months/year
-
-
MMBtu
03: 2.7493 USE DOUBLE OR TRIPLE GLAZED WINDOWS TO MAINTAIN HIGHER RELATIVE HUMIDITY AND TO REDUCE HEAT LOSSES Savings:
$18,500
Cost:
$12,889
$18,500 179,608 - - - - $18,500
179,608
kWh
-
-
kW-months/year
-
-
MMBtu
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$15,170
Cost:
$13,688
$12,991 126,126 $2,179 529 - - $12,991
126,126
kWh
$2,179
529
kW-months/year
-
-
MMBtu
05: 2.1224 REPLACE BOILER Savings:
$4,808
Cost:
$10,080
- - - - $4,808 324 -
-
kWh
-
-
kW-months/year
$4,808
324
MMBtu
TOTAL RECOMMENDED Savings:
$49,925
Cost:
$38,707
$42,938 416,868 $2,179 529 $4,808 324 $42,938
416,868
kWh
$2,179
529
kW-months/year
$4,808
324
MMBtu
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - - - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
Savings
Cost
$ kWh $ kW-months/year $ MMBtu
Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas