IAC Center | Louisiana State University |
---|---|
Assessment Year | 2020 |
Principal Product | Wastewater/Sewage Treatment |
NAICS | 221320 - Sewage Treatment Facilities |
SIC | 4952 - Sewerage Systems |
Sales | $80,001 |
# of Employees | 21 |
Plant Area (Sq.Ft.) | 780,000 |
Annual Production | 5,475,000 Thousand Gallons |
Production Hrs. Annual | 8,760 |
Location (State) | LA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $563,344 | 9,996,000 | kWh | $0.06 |
Electricity Demand | $98,880 | 24,000 | kW/month | $4.12 |
Natural Gas | $44,864 | 7,187 | MMBtu | $6.24 |
TOTAL ENERGY COSTS | $707,088 | |||
RECOMMENDED SAVINGS* | $205,464 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Usage | Electricity Demand | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW/month | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS |
Savings: $1,297 Cost: $6 |
$1,297 | 23,020 | - | - |
$1,297 23,020 kWh |
- - kW/month |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $25,814 Cost: $6,317 |
$23,373 | 414,736 | $2,441 | 593 |
$23,373 414,736 kWh |
$2,441 593 kW/month |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7124 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED |
Savings: $1,753 Cost: $500 |
$1,753 | 31,098 | - | - |
$1,753 31,098 kWh |
- - kW/month |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $458 Cost: $158 |
$458 | 8,130 | - | - |
$458 8,130 kWh |
- - kW/month |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4322 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES |
Savings: $89,345 Cost: $41,575 |
$81,212 | 1,441,020 | $8,133 | 1,974 |
$81,212 1,441,020 kWh |
$8,133 1,974 kW/month |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $86,774 Cost: $49,800 |
$86,774 | 1,539,727 | - | - |
$86,774 1,539,727 kWh |
- - kW/month |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $23 Cost: $25 |
$23 | 400 | - | - |
$23 400 kWh |
- - kW/month |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $205,464 Cost: $98,381 |
$194,890 | 3,458,131 | $10,574 | 2,567 | $194,890 3,458,131 kWh |
$10,574 2,567 kW/month |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - - kWh |
- - kW/month |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW/month | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Usage | Electricity Demand |