IAC logo
IAC Assessment: LS2005
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: LS2005
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Louisiana State University
Assessment Year 2020
Principal Product Plastic Conveyor Components
NAICS 326199 - All Other Plastics Product Manufacturing
SIC 3089 - Plastics Products, Nec
Sales $100,000,000-$500,000,000
# of Employees 150
Plant Area (Sq.Ft.) 224,790
Annual Production 16,000,000 Pounds
Production Hrs. Annual 8,760
Location (State) LA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $1,268,638 19,468,800 kWh $0.07
TOTAL ENERGY COSTS $1,268,638
RECOMMENDED SAVINGS* $261,359 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $2,834
#|Description Savings
Cost
Status Electricity Usage Electricity Usage
$ kWh
01: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS Savings:
$2,727
Cost:
$300
$2,727 41,850 $2,727
41,850
kWh
02: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$2,560
Cost:
-
$2,560 39,287 $2,560
39,287
kWh
03: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$114
Cost:
$50
$114 1,747 $114
1,747
kWh
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$30,208
Cost:
$17,766
$30,208 463,577 $30,208
463,577
kWh
05: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$274
Cost:
-
$274 4,204 $274
4,204
kWh
06: 2.2622 REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL Savings:
$225,476
Cost:
$1,204,486
$225,476 3,460,205 $225,476
3,460,205
kWh
TOTAL RECOMMENDED Savings:
$261,359
Cost:
$1,222,602
$261,359 4,010,870 $261,359
4,010,870
kWh
TOTAL IMPLEMENTED Savings:
$2,834
Cost:
-
$2,834 43,491 $2,834
43,491
kWh
Savings
Cost
$ kWh
Electricity Usage Electricity Usage