Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Louisiana State University
Assessment Year 2021
Principal Product Conveyor Plastic Belt
NAICS 326199 - All Other Plastics Product Manufacturing
SIC 3089 - Plastics Products, Nec
Sales <$500,000
# of Employees 263
Plant Area (Sq.Ft.) 162,143
Annual Production 16,000,000 Pounds
Production Hrs. Annual 8,760
Location (State) LA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $2,181,491 32,942,136 kWh $0.07
TOTAL ENERGY COSTS $2,181,491
RECOMMENDED SAVINGS* $285,200 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $285,200
#|Description Savings
Cost
Status Electricity Usage Electricity Usage
$ kWh
01: 2.2625 CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE Savings:
$35,907
Cost:
$250
$35,907 542,229 $35,907
542,229
kWh
02: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$2,807
Cost:
$428
$2,807 42,386 $2,807
42,386
kWh
03: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$5,440
Cost:
$900
$5,440 82,147 $5,440
82,147
kWh
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$31,154
Cost:
$39,829
$31,154 470,455 $31,154
470,455
kWh
05: 2.2622 REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL Savings:
$209,892
Cost:
$1,023,215
$209,892 3,169,524 $209,892
3,169,524
kWh
TOTAL RECOMMENDED Savings:
$285,200
Cost:
$1,064,622
$285,200 4,306,741 $285,200
4,306,741
kWh
TOTAL IMPLEMENTED Savings:
$285,200
Cost:
$1,064,622
$285,200 4,306,741 $285,200
4,306,741
kWh
Savings
Cost
$ kWh
Electricity Usage Electricity Usage