Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Louisiana State University |
---|---|
Assessment Year | 2022 |
Principal Product | Metal Fabrication |
NAICS | 332312 - Fabricated Structural Metal Manufacturing |
SIC | 3441 - Fabricated Structural Metal |
Sales | $1,000,000-$5,000,000 |
# of Employees | 10 |
Plant Area (Sq.Ft.) | 35,000 |
Annual Production | 50,000 Units |
Production Hrs. Annual | 2,444 |
Location (State) | LA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $80,701 | 812,945 | kWh | $0.10 |
Electricity Demand | $10,668 | 2,784 | kW-months/year | $3.83 |
Fuel Oil #2 | $10,000 | 417 | MMBtu | $23.98 |
TOTAL ENERGY COSTS | $101,369 | |||
RECOMMENDED SAVINGS* | $66,456 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $22,237 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Other Liquid (non-haz) | Electricity Usage | Electricity Demand | Electricity Fees | Other Liquid (non-haz) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | gal | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $242 Cost: $25 |
$242 | 2,437 | - | - | - | - | - | - |
$242 2,437 kWh |
- - kW-months/year |
- - $ |
- - gal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $6,612 Cost: $675 |
$6,612 | 66,789 | - | - | - | - | - | - |
$6,612 66,789 kWh |
- - kW-months/year |
- - $ |
- - gal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $199 Cost: $53 |
$164 | 1,660 | $35 | 9 | - | - | - | - |
$164 1,660 kWh |
$35 9 kW-months/year |
- - $ |
- - gal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7444 CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS |
Savings: $121 Cost: $49 |
$121 | 1,218 | - | - | - | - | - | - |
$121 1,218 kWh |
- - kW-months/year |
- - $ |
- - gal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7447 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS |
Savings: $482 Cost: $240 |
$482 | 4,867 | - | - | - | - | - | - |
$482 4,867 kWh |
- - kW-months/year |
- - $ |
- - gal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $99 Cost: $50 |
$99 | 999 | - | - | - | - | - | - |
$99 999 kWh |
- - kW-months/year |
- - $ |
- - gal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 3.2142 USE TANKS WITH A CONICAL BOTTOM OUTLET SECTION TO REDUCE WASTE ASSOCIATED WITH THE INTERFACE OF TWO LIQUIDS |
Savings: $1,451 Cost: $1,103 |
- | - | - | - | - | - | $1,451 | 100 |
- - kWh |
- - kW-months/year |
- - $ |
$1,451 100 gal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7232 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL |
Savings: $15,305 Cost: $31,464 |
$15,305 | 154,595 | - | - | - | - | - | - |
$15,305 154,595 kWh |
- - kW-months/year |
- - $ |
- - gal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $464 Cost: $3,415 |
- | - | - | - | $464 | - | - | - |
- - kWh |
- - kW-months/year |
$464 - $ |
- - gal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY |
Savings: $41,481 Cost: $646,020 |
$41,481 | 419,000 | - | - | - | - | - | - |
$41,481 419,000 kWh |
- - kW-months/year |
- - $ |
- - gal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $66,456 Cost: $683,094 |
$64,506 | 651,565 | $35 | 9 | $464 | - | $1,451 | 100 | $64,506 651,565 kWh |
$35 9 kW-months/year |
$464 - $ |
$1,451 100 gal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $22,237 Cost: $32,241 |
$22,202 | 224,262 | $35 | 9 | - | - | - | - | $22,202 224,262 kWh |
$35 9 kW-months/year |
- - $ |
- - gal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | gal | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Other Liquid (non-haz) | Electricity Usage | Electricity Demand | Electricity Fees | Other Liquid (non-haz) |