Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Louisiana State University |
---|---|
Assessment Year | 2025 |
Principal Product | Calcine |
NAICS | 324199 - All Other Petroleum and Coal Products Manufacturing |
SIC | 2999 - Petroleum And Coal Products, Nec |
Sales | $100,000,000-$500,000,000 |
# of Employees | 67 |
Plant Area (Sq.Ft.) | 215,372 |
Annual Production | 800,000,000 Pounds |
Production Hrs. Annual | 8,760 |
Location (State) | LA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $480,792 | 6,648,600 | kWh | $0.07 |
Electricity Demand | $45,567 | 10,896 | kW-months/year | $4.18 |
Natural Gas | $716,742 | 286,856 | MMBtu | $2.50 |
Other Energy | $317,564 | 10,902 | MMBtu | $29.13 |
TOTAL ENERGY COSTS | $1,560,665 | |||
RECOMMENDED SAVINGS* | $507,065 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Natural Gas | Other Energy | Administrative Changes | Primary Product | Electricity Usage | Natural Gas | Other Energy | Administrative Changes | Primary Product | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | MMBtu | $ | MMBtu | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4226 USE / PURCHASE OPTIMUM SIZED COMPRESSOR |
Savings: $40,834 Cost: $25,000 |
$40,834 | 567,141 | - | - | - | - | - | - | - | - |
$40,834 567,141 kWh |
- - MMBtu |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4131 SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY |
Savings: $12,547 Cost: $16,300 |
$12,547 | 174,266 | - | - | - | - | - | - | - | - |
$12,547 174,266 kWh |
- - MMBtu |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 3.7221 IMPROVE PROCESS CONTROL TO PREVENT SPILLS OF MATERIAL |
Savings: $56,956 Cost: $80,000 |
- | - | - | - | - | - | $55,000 | - | $1,956 | - |
- - kWh |
- - MMBtu |
- - MMBtu |
$55,000 - $ |
$1,956 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 4.652 REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES |
Savings: $127,011 Cost: $200,000 |
$2,719 | 37,769 | - | - | - | - | $124,292 | - | - | - |
$2,719 37,769 kWh |
- - MMBtu |
- - MMBtu |
$124,292 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $1,218 Cost: $2,700 |
$1,218 | 16,921 | - | - | - | - | - | - | - | - |
$1,218 16,921 kWh |
- - MMBtu |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.1321 REPLACE FOSSIL FUEL EQUIPMENT WITH ELECTRICAL EQUIPMENT |
Savings: $53,529 Cost: $144,549 |
$(-2,076) | (-28,829) | - | - | $31,605 | 1,085 | $24,000 | - | - | - |
$(-2,076) (-28,829) kWh |
- - MMBtu |
$31,605 1,085 MMBtu |
$24,000 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $214,970 Cost: $1,500,000 |
- | - | $214,970 | 86,057 | - | - | - | - | - | - |
- - kWh |
$214,970 86,057 MMBtu |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $507,065 Cost: $1,968,549 |
$55,242 | 767,268 | $214,970 | 86,057 | $31,605 | 1,085 | $203,292 | - | $1,956 | - | $55,242 767,268 kWh |
$214,970 86,057 MMBtu |
$31,605 1,085 MMBtu |
$203,292 - $ |
$1,956 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - | - | - - kWh |
- - MMBtu |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | MMBtu | $ | MMBtu | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Natural Gas | Other Energy | Administrative Changes | Primary Product | Electricity Usage | Natural Gas | Other Energy | Administrative Changes | Primary Product |