Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Louisiana State University |
---|---|
Assessment Year | 2025 |
Principal Product | Bottled Water |
NAICS | 312112 - Bottled Water Manufacturing |
SIC | 2086 - Bottled And Canned Soft Drinks |
Sales | $10,000,000-$50,000,000 |
# of Employees | 15 |
Plant Area (Sq.Ft.) | 76,345 |
Annual Production | 11,000,000 Units |
Production Hrs. Annual | 2,184 |
Location (State) | LA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $163,018 | 2,672,212 | kWh | $0.06 |
Electricity Demand | $263,937 | 16,223 | kW-months/year | $16.27 |
Natural Gas | $9,046 | 619 | MMBtu | $14.61 |
LPG | $14,400 | 110 | MMBtu | $130.91 |
TOTAL ENERGY COSTS | $461,081 | |||
RECOMMENDED SAVINGS* | $151,419 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | LPG | Solid Waste (non-haz) | Administrative Changes | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | LPG | Solid Waste (non-haz) | Administrative Changes | One-time Revenue or Avoided Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | lb | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 3.5212 REGRIND, REUSE, OR SELL SCRAP PLASTIC PARTS |
Savings: $12,408 Cost: - |
- | - | - | - | - | - | $10,680 | 34,560 | - | - | $1,728 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$10,680 34,560 lb |
- - $ |
$1,728 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS |
Savings: $10,625 Cost: $35 |
$10,625 | 174,177 | - | - | - | - | - | - | - | - | - | - |
$10,625 174,177 kWh |
- - kW-months/year |
- - MMBtu |
- - lb |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $4,245 Cost: $6,160 |
$1,723 | 28,282 | $2,522 | 155 | - | - | - | - | - | - | - | - |
$1,723 28,282 kWh |
$2,522 155 kW-months/year |
- - MMBtu |
- - lb |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.1321 REPLACE FOSSIL FUEL EQUIPMENT WITH ELECTRICAL EQUIPMENT |
Savings: $37,258 Cost: $144,549 |
$(-1,142) | (-18,720) | - | - | $14,400 | 110 | - | - | $24,000 | - | - | - |
$(-1,142) (-18,720) kWh |
- - kW-months/year |
$14,400 110 MMBtu |
- - lb |
$24,000 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7425 CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD |
Savings: $5,344 Cost: $26,721 |
$5,344 | 87,607 | - | - | - | - | - | - | - | - | - | - |
$5,344 87,607 kWh |
- - kW-months/year |
- - MMBtu |
- - lb |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY |
Savings: $25,948 Cost: $187,200 |
$25,948 | 425,381 | - | - | - | - | - | - | - | - | - | - |
$25,948 425,381 kWh |
- - kW-months/year |
- - MMBtu |
- - lb |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 4.652 REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES |
Savings: $55,591 Cost: $576,000 |
$1,279 | 20,967 | - | - | - | - | - | - | $54,312 | - | - | - |
$1,279 20,967 kWh |
- - kW-months/year |
- - MMBtu |
- - lb |
$54,312 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $151,419 Cost: $940,665 |
$43,777 | 717,694 | $2,522 | 155 | $14,400 | 110 | $10,680 | 34,560 | $78,312 | - | $1,728 | - | $43,777 717,694 kWh |
$2,522 155 kW-months/year |
$14,400 110 MMBtu |
$10,680 34,560 lb |
$78,312 - $ |
$1,728 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - MMBtu |
- - lb |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | lb | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||