Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Louisiana Tech
Assessment Year 2023
Principal Product Municipal wastewater
NAICS 221320 - Sewage Treatment Facilities
SIC 4952 - Sewerage Systems
Sales $500,000-$1,000,000
# of Employees 15
Plant Area (Sq.Ft.) 575,000
Annual Production 365,000 Thousand Gallons
Production Hrs. Annual 8,760
Location (State) LA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $229,936 2,490,593 kWh $0.09
TOTAL ENERGY COSTS $229,936
RECOMMENDED SAVINGS* $101,238 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Electricity Usage
$ kWh
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$1,997
Cost:
$2,973
$1,997 21,631 $1,997
21,631
kWh
02: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY Savings:
$69,836
Cost:
$1,164,586
$69,836 756,618 $69,836
756,618
kWh
03: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$29,363
Cost:
$43,171
$29,363 318,121 $29,363
318,121
kWh
04: 2.7232 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL Savings:
$43
Cost:
$276
$43 464 $43
464
kWh
TOTAL RECOMMENDED Savings:
$101,238
Cost:
$1,211,006
$101,238 1,096,834 $101,238
1,096,834
kWh
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - -
-
kWh
Savings
Cost
$ kWh
Electricity Usage Electricity Usage