IAC logo
IAC Assessment: LT8406
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: LT8406
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Louisiana Tech
Assessment Year 2024
Principal Product Educational Resource
NAICS 712110 - Museums
SIC 8412 - Museums And Art Galleries
Sales $1,000,000-$5,000,000
# of Employees 25
Plant Area (Sq.Ft.) 92,000
Annual Production 74,000 Units
Production Hrs. Annual 1,500
Location (State) LA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $207,351 2,990,700 kWh $0.07
Electricity Demand $81,508 6,423 kW-months/year $12.69
TOTAL ENERGY COSTS $291,748
RECOMMENDED SAVINGS* $105,066 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Ancillary Material Cost Electricity Usage Electricity Demand Ancillary Material Cost
$ kWh $ kW-months/year $ $
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$13,584
Cost:
$13,892
$12,966 187,919 $617 49 - - $12,966
187,919
kWh
$617
49
kW-months/year
-
-
$
02: 2.2691 SHUT OFF COOLING IF COLD OUTSIDE AIR WILL COOL PROCESS Savings:
$89,448
Cost:
-
$88,728 1,285,910 - - $720 - $88,728
1,285,910
kWh
-
-
kW-months/year
$720
-
$
03: 2.7442 KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE Savings:
$1,624
Cost:
$750
$670 9,708 $954 75 - - $670
9,708
kWh
$954
75
kW-months/year
-
-
$
04: 2.7444 CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS Savings:
$410
Cost:
$360
$351 5,084 $60 5 - - $351
5,084
kWh
$60
5
kW-months/year
-
-
$
TOTAL RECOMMENDED Savings:
$105,066
Cost:
$15,002
$102,715 1,488,620 $1,631 129 $720 - $102,715
1,488,620
kWh
$1,631
129
kW-months/year
$720
-
$
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - - - -
-
kWh
-
-
kW-months/year
-
-
$
Savings
Cost
$ kWh $ kW-months/year $ $
Electricity Usage Electricity Demand Ancillary Material Cost Electricity Usage Electricity Demand Ancillary Material Cost