Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Massachusetts
Assessment Year 1985
Principal Product THERMOSET PLASTICS
NAICS n/a
SIC 3083 - Laminated Plastics Plate & Sheet
Sales $1,000,000-$5,000,000
# of Employees 45
Plant Area (Sq.Ft.) 0
Annual Production 5,250,000 Pounds
Production Hrs. Annual 5,880
Location (State) MA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $46,690 579,132 kWh $0.08
Natural Gas $5,318 758 MMBtu $7.02
Wood $638 731 MMBtu $0.87
TOTAL ENERGY COSTS $52,646
RECOMMENDED SAVINGS* $10,628 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $4,286
#|Description Savings
Cost
Status Electricity Usage Natural Gas Administrative Changes Electricity Usage Natural Gas Administrative Changes
$ kWh $ MMBtu $ $
01: 2.6124 ESTABLISH EQUIPMENT MAINTENANCE SCHEDULE Savings:
$454
Cost:
-
- - $659 94 $(-205) - -
-
kWh
$659
94
MMBtu
$(-205)
-
$
02: 3.6123 BURN WOOD BY-PRODUCTS FOR HEAT Savings:
$2,010
Cost:
$8,450
- - $2,215 316 $(-205) - -
-
kWh
$2,215
316
MMBtu
$(-205)
-
$
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$1,822
Cost:
$105
$1,822 22,567 - - - - $1,822
22,567
kWh
-
-
MMBtu
-
-
$
04: 2.7229 AIR CONDITION ONLY SPACE NECESSARY Savings:
$435
Cost:
$100
- - $435 62 - - -
-
kWh
$435
62
MMBtu
-
-
$
05: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT Savings:
$2,005
Cost:
$3,702
- - $2,005 286 - - -
-
kWh
$2,005
286
MMBtu
-
-
$
06: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$3,902
Cost:
$4,380
$3,902 48,359 - - - - $3,902
48,359
kWh
-
-
MMBtu
-
-
$
TOTAL RECOMMENDED Savings:
$10,628
Cost:
$16,737
$5,724 70,926 $5,314 758 $(-410) - $5,724
70,926
kWh
$5,314
758
MMBtu
$(-410)
-
$
TOTAL IMPLEMENTED Savings:
$4,286
Cost:
$8,555
$1,822 22,567 $2,874 410 $(-410) - $1,822
22,567
kWh
$2,874
410
MMBtu
$(-410)
-
$
Savings
Cost
$ kWh $ MMBtu $ $
Electricity Usage Natural Gas Administrative Changes Electricity Usage Natural Gas Administrative Changes