IAC logo
IAC Assessment: MA0162
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: MA0162
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Massachusetts
Assessment Year 1989
Principal Product HARDWARE
NAICS n/a
SIC 3471 - Plating And Polishing
Sales $10,000,000-$50,000,000
# of Employees 300
Plant Area (Sq.Ft.) 0
Annual Production 0 Units
Production Hrs. Annual 4,250
Location (State) CT
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $340,151 4,837,925 kWh $0.07
Natural Gas $13,015 2,367 MMBtu $5.50
Fuel Oil #6 $97,164 34,504 MMBtu $2.82
TOTAL ENERGY COSTS $450,330
RECOMMENDED SAVINGS* $27,182 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $936
#|Description Savings
Cost
Status Electricity Usage Fuel Oil #6 Electricity Usage Fuel Oil #6
$ kWh $ MMBtu
01: 2.3191 USE DEMAND CONTROLLER OR LOAD SHEDDER Savings:
$936
Cost:
$75
$936 - - - $936
-
kWh
-
-
MMBtu
02: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$665
Cost:
$50
$665 9,379 - - $665
9,379
kWh
-
-
MMBtu
03: 2.3312 INSTALL EFFICIENT RECTIFIERS Savings:
$14,209
Cost:
$8,500
$14,209 202,227 - - $14,209
202,227
kWh
-
-
MMBtu
04: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$1,765
Cost:
$400
$1,765 25,205 - - $1,765
25,205
kWh
-
-
MMBtu
05: 2.1131 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC Savings:
$636
Cost:
$1,041
- - $636 226 -
-
kWh
$636
226
MMBtu
06: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$8,259
Cost:
$14,920
$5,254 74,736 $3,005 1,066 $5,254
74,736
kWh
$3,005
1,066
MMBtu
07: 2.6232 INSTALL SET-BACK TIMERS Savings:
$712
Cost:
$150
$712 10,258 - - $712
10,258
kWh
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$27,182
Cost:
$25,136
$23,541 321,805 $3,641 1,292 $23,541
321,805
kWh
$3,641
1,292
MMBtu
TOTAL IMPLEMENTED Savings:
$936
Cost:
$75
$936 - - - $936
-
kWh
-
-
MMBtu
Savings
Cost
$ kWh $ MMBtu
Electricity Usage Fuel Oil #6 Electricity Usage Fuel Oil #6