Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Massachusetts
Assessment Year 1991
Principal Product NON-WOVEN FABRICS
NAICS n/a
SIC 2299 - Textile Goods, Nec
Sales $10,000,000-$50,000,000
# of Employees 200
Plant Area (Sq.Ft.) 0
Annual Production 27,900 Thousand Feet
Production Hrs. Annual 7,488
Location (State) NH
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $563,915 7,590,856 kWh $0.07
LPG $131,238 25,003 MMBtu $5.25
Fuel Oil #6 $138,957 43,398 MMBtu $3.20
TOTAL ENERGY COSTS $834,110
RECOMMENDED SAVINGS* $179,558 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $32,693
#|Description Savings
Cost
Status Electricity Usage LPG Fuel Oil #6 Administrative Changes Electricity Usage LPG Fuel Oil #6 Administrative Changes
$ kWh $ MMBtu $ MMBtu $ $
01: 2.1311 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT Savings:
$46,881
Cost:
-
$56,316 758,206 $(-9,435) (-1,797) - - - - $56,316
758,206
kWh
$(-9,435)
(-1,797)
MMBtu
-
-
MMBtu
-
-
$
02: 2.1311 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT Savings:
$71,552
Cost:
-
$88,325 1,189,039 $(-16,773) (-3,195) - - - - $88,325
1,189,039
kWh
$(-16,773)
(-3,195)
MMBtu
-
-
MMBtu
-
-
$
03: 2.2444 USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS Savings:
$25,667
Cost:
$19,927
- - $25,667 4,889 - - - - -
-
kWh
$25,667
4,889
MMBtu
-
-
MMBtu
-
-
$
04: 2.2113 REPAIR OR REPLACE STEAM TRAPS Savings:
$21,213
Cost:
$35,000
- - - - $24,093 7,529 $(-2,880) - -
-
kWh
-
-
MMBtu
$24,093
7,529
MMBtu
$(-2,880)
-
$
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$8,079
Cost:
$16,200
$8,079 108,734 - - - - - - $8,079
108,734
kWh
-
-
MMBtu
-
-
MMBtu
-
-
$
06: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$2,765
Cost:
$1,500
$2,765 37,222 - - - - - - $2,765
37,222
kWh
-
-
MMBtu
-
-
MMBtu
-
-
$
07: 2.2511 INSULATE BARE EQUIPMENT Savings:
$1,859
Cost:
$2,250
- - - - $1,859 581 - - -
-
kWh
-
-
MMBtu
$1,859
581
MMBtu
-
-
$
08: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT Savings:
$1,542
Cost:
$1,060
- - - - $1,542 482 - - -
-
kWh
-
-
MMBtu
$1,542
482
MMBtu
-
-
$
TOTAL RECOMMENDED Savings:
$179,558
Cost:
$75,937
$155,485 2,093,201 $(-541) (-103) $27,494 8,592 $(-2,880) - $155,485
2,093,201
kWh
$(-541)
(-103)
MMBtu
$27,494
8,592
MMBtu
$(-2,880)
-
$
TOTAL IMPLEMENTED Savings:
$32,693
Cost:
$54,510
$8,079 108,734 - - $27,494 8,592 $(-2,880) - $8,079
108,734
kWh
-
-
MMBtu
$27,494
8,592
MMBtu
$(-2,880)
-
$
Savings
Cost
$ kWh $ MMBtu $ MMBtu $ $
Electricity Usage LPG Fuel Oil #6 Administrative Changes Electricity Usage LPG Fuel Oil #6 Administrative Changes