IAC logo
IAC Assessment: MA0234
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: MA0234
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Massachusetts
Assessment Year 1992
Principal Product RECYCLABLE PAPER
NAICS n/a
SIC 2621 - Paper Mills
Sales $5,000,000-$10,000,000
# of Employees 30
Plant Area (Sq.Ft.) 0
Annual Production 13,000 Tons
Production Hrs. Annual 6,240
Location (State) NH
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $775,711 10,079,133 kWh $0.08
Fuel Oil #6 $213,359 85,343 MMBtu $2.50
TOTAL ENERGY COSTS $989,070
RECOMMENDED SAVINGS* $160,136 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $118,305
#|Description Savings
Cost
Status Electricity Usage Fuel Oil #6 Administrative Changes Electricity Usage Fuel Oil #6 Administrative Changes
$ kWh $ MMBtu $ $
01: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$95,700
Cost:
$153,525
$95,700 1,243,259 - - - - $95,700
1,243,259
kWh
-
-
MMBtu
-
-
$
02: 2.2443 RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR Savings:
$38,424
Cost:
$77,755
$(-12,566) (-163,247) $50,990 20,396 - - $(-12,566)
(-163,247)
kWh
$50,990
20,396
MMBtu
-
-
$
03: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO Savings:
$13,505
Cost:
$24,600
- - $13,505 5,402 - - -
-
kWh
$13,505
5,402
MMBtu
-
-
$
04: 2.2136 INSTALL / REPAIR INSULATION ON STEAM LINES Savings:
$9,100
Cost:
$3,720
- - $9,100 3,640 - - -
-
kWh
$9,100
3,640
MMBtu
-
-
$
05: 2.1213 DIRECT WARMEST AIR TO COMBUSTION INTAKE Savings:
$2,845
Cost:
$4,162
- - $2,845 1,138 - - -
-
kWh
$2,845
1,138
MMBtu
-
-
$
06: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$562
Cost:
-
$779 10,258 - - $(-217) - $779
10,258
kWh
-
-
MMBtu
$(-217)
-
$
TOTAL RECOMMENDED Savings:
$160,136
Cost:
$263,762
$83,913 1,090,270 $76,440 30,576 $(-217) - $83,913
1,090,270
kWh
$76,440
30,576
MMBtu
$(-217)
-
$
TOTAL IMPLEMENTED Savings:
$118,305
Cost:
$181,845
$95,700 1,243,259 $22,605 9,042 - - $95,700
1,243,259
kWh
$22,605
9,042
MMBtu
-
-
$
Savings
Cost
$ kWh $ MMBtu $ $
Electricity Usage Fuel Oil #6 Administrative Changes Electricity Usage Fuel Oil #6 Administrative Changes