Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Massachusetts
Assessment Year 1992
Principal Product RADIATORS,AIR SYSTEMS
NAICS n/a
SIC 3433 - Heating Equipment, Except Electric
Sales $10,000,000-$50,000,000
# of Employees 110
Plant Area (Sq.Ft.) 0
Annual Production 1,000,000 Pounds
Production Hrs. Annual 2,125
Location (State) CT
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $127,398 1,435,229 kWh $0.09
Natural Gas $69,965 11,211 MMBtu $6.24
Fuel Oil #2 $2,649 75,600 MMBtu $0.04
TOTAL ENERGY COSTS $200,012
RECOMMENDED SAVINGS* $5,322 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $3,382
#|Description Savings
Cost
Status Electricity Usage Electricity Usage
$ kWh
01: 2.6232 INSTALL SET-BACK TIMERS Savings:
$822
Cost:
$528
$822 9,379 $822
9,379
kWh
02: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$156
Cost:
-
$156 1,758 $156
1,758
kWh
03: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$494
Cost:
$319
$494 5,569 $494
5,569
kWh
04: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$1,327
Cost:
$300
$1,327 14,947 $1,327
14,947
kWh
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$1,405
Cost:
$3,381
$1,405 15,826 $1,405
15,826
kWh
06: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE Savings:
$1,118
Cost:
$246
$1,118 12,603 $1,118
12,603
kWh
TOTAL RECOMMENDED Savings:
$5,322
Cost:
$4,774
$5,322 60,082 $5,322
60,082
kWh
TOTAL IMPLEMENTED Savings:
$3,382
Cost:
$4,000
$3,382 38,100 $3,382
38,100
kWh
Savings
Cost
$ kWh
Electricity Usage Electricity Usage