Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Massachusetts |
---|---|
Assessment Year | 1996 |
Principal Product | electrical wire |
NAICS | n/a |
SIC | 3699 - Electrical Equipment & Supplies, Nec |
Sales | $10,000,000-$50,000,000 |
# of Employees | 165 |
Plant Area (Sq.Ft.) | 550,000 |
Annual Production | 385,000 Thousand Feet |
Production Hrs. Annual | 6,000 |
Location (State) | NH |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $471,798 | 4,581,770 | kWh | $0.10 |
Electricity Demand | $69,612 | 10,223 | kW-months/year | $6.81 |
Natural Gas | $74,233 | 12,014 | MMBtu | $6.18 |
TOTAL ENERGY COSTS | $617,893 | |||
RECOMMENDED SAVINGS* | $58,061 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Other Liquid (non-haz) | Solid Waste (non-haz) | Electricity Usage | Electricity Demand | Natural Gas | Other Liquid (non-haz) | Solid Waste (non-haz) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | gal | $ | lb | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7293 INSTALL DRY SPRINKLER SYSTEM OR OTHER METHOD TO REDUCE HEATING REQUIREMENTS |
Savings: $25,870 Cost: $11,700 |
- | - | - | - | $25,870 | 4,241 | - | - | - | - |
- - kWh |
- - kW-months/year |
$25,870 4,241 MMBtu |
- - gal |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $4,515 Cost: $822 |
$4,515 | 54,220 | - | - | - | - | - | - | - | - |
$4,515 54,220 kWh |
- - kW-months/year |
- - MMBtu |
- - gal |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $2,149 Cost: $341 |
$2,149 | 25,791 | - | - | - | - | - | - | - | - |
$2,149 25,791 kWh |
- - kW-months/year |
- - MMBtu |
- - gal |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $6,420 Cost: $9,000 |
- | - | - | - | $6,420 | 1,070 | - | - | - | - |
- - kWh |
- - kW-months/year |
$6,420 1,070 MMBtu |
- - gal |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4314 USE SYNTHETIC LUBRICANT |
Savings: $1,687 Cost: - |
$1,696 | 20,223 | - | - | - | - | $(-9) | 58 | - | - |
$1,696 20,223 kWh |
- - kW-months/year |
- - MMBtu |
$(-9) 58 gal |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.2136 INSTALL / REPAIR INSULATION ON STEAM LINES |
Savings: $1,195 Cost: $645 |
- | - | - | - | $1,195 | 196 | - | - | - | - |
- - kWh |
- - kW-months/year |
$1,195 196 MMBtu |
- - gal |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.2611 MODERATE COOLING TOWER OUTLET TEMPERATURE |
Savings: $2,124 Cost: $5,084 |
$2,124 | 25,498 | - | - | - | - | - | - | - | - |
$2,124 25,498 kWh |
- - kW-months/year |
- - MMBtu |
- - gal |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $12,954 Cost: $51,942 |
$10,056 | 120,750 | $2,898 | 375 | - | - | - | - | - | - |
$10,056 120,750 kWh |
$2,898 375 kW-months/year |
- - MMBtu |
- - gal |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 3.4145 USE MAGNETIC TECHNOLOGY TO TREAT WATER |
Savings: $1,147 Cost: $2,800 |
- | - | - | - | - | - | - | - | $1,147 | 556 |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - gal |
$1,147 556 lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $58,061 Cost: $82,334 |
$20,540 | 246,482 | $2,898 | 375 | $33,485 | 5,507 | $(-9) | 58 | $1,147 | 556 | $20,540 246,482 kWh |
$2,898 375 kW-months/year |
$33,485 5,507 MMBtu |
$(-9) 58 gal |
$1,147 556 lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - MMBtu |
- - gal |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | gal | $ | lb | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||