Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Massachusetts |
---|---|
Assessment Year | 2000 |
Principal Product | Carbon Seals and Bearings |
NAICS | n/a |
SIC | 3568 - Power Transmission Equipment, Nec |
Sales | $10,000,000-$50,000,000 |
# of Employees | 140 |
Plant Area (Sq.Ft.) | 55,000 |
Annual Production | 600,000 Pounds |
Production Hrs. Annual | 6,240 |
Location (State) | RI |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $405,593 | 6,592,907 | kWh | $0.06 |
Electricity Demand | $36,016 | 12,720 | kW-months/year | $2.83 |
Electricity Fees | $3,134 | - | $ | - |
Natural Gas | $82,243 | 16,113 | MMBtu | $5.10 |
TOTAL ENERGY COSTS | $558,416 | |||
RECOMMENDED SAVINGS* | $118,531 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $19,769 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | By-product Production | Electricity Usage | Electricity Demand | Natural Gas | By-product Production | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.1311 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT |
Savings: $69,572 Cost: $286,600 |
$88,211 | 1,379,543 | $7,191 | 2,541 | $(-25,830) | (-5,884) | - | - |
$88,211 1,379,543 kWh |
$7,191 2,541 kW-months/year |
$(-25,830) (-5,884) MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.1311 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT |
Savings: $22,135 Cost: $42,000 |
$27,923 | 436,694 | $2,377 | 870 | $(-8,165) | (-1,860) | - | - |
$27,923 436,694 kWh |
$2,377 870 kW-months/year |
$(-8,165) (-1,860) MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $6,240 Cost: $26,115 |
$6,240 | 97,597 | - | - | - | - | - | - |
$6,240 97,597 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.2692 USE OUTSIDE COLD WATER SOURCE AS A SUPPLY OF COOLING WATER |
Savings: $5,388 Cost: $13,800 |
$4,966 | 77,667 | $422 | 149 | - | - | - | - |
$4,966 77,667 kWh |
$422 149 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7313 RECYCLE AIR FOR HEATING, VENTILATION AND AIR CONDITIONING |
Savings: $4,828 Cost: $1,960 |
$2,755 | 43,083 | - | - | $7,353 | 1,675 | $(-5,280) | - |
$2,755 43,083 kWh |
- - kW-months/year |
$7,353 1,675 MMBtu |
$(-5,280) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $4,880 Cost: $32,900 |
$4,498 | 70,340 | $382 | 135 | - | - | - | - |
$4,498 70,340 kWh |
$382 135 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $2,435 Cost: $300 |
$2,435 | 45,721 | - | - | - | - | - | - |
$2,435 45,721 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $1,423 Cost: $1,070 |
$1,423 | 22,274 | - | - | - | - | - | - |
$1,423 22,274 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $815 Cost: $3,075 |
$750 | 11,723 | $65 | 23 | - | - | - | - |
$750 11,723 kWh |
$65 23 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $815 Cost: $300 |
$750 | 11,723 | $65 | 23 | - | - | - | - |
$750 11,723 kWh |
$65 23 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $118,531 Cost: $408,120 |
$139,951 | 2,196,365 | $10,502 | 3,741 | $(-26,642) | (-6,069) | $(-5,280) | - | $139,951 2,196,365 kWh |
$10,502 3,741 kW-months/year |
$(-26,642) (-6,069) MMBtu |
$(-5,280) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $19,769 Cost: $50,330 |
$16,827 | 270,808 | $869 | 307 | $7,353 | 1,675 | $(-5,280) | - | $16,827 270,808 kWh |
$869 307 kW-months/year |
$7,353 1,675 MMBtu |
$(-5,280) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | By-product Production | Electricity Usage | Electricity Demand | Natural Gas | By-product Production |