Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Massachusetts |
---|---|
Assessment Year | 2001 |
Principal Product | Abrasive stones |
NAICS | n/a |
SIC | 3291 - Abrasive Products |
Sales | $10,000,000-$50,000,000 |
# of Employees | 54 |
Plant Area (Sq.Ft.) | 90,000 |
Annual Production | 1,225,000 Pounds |
Production Hrs. Annual | 8,450 |
Location (State) | NH |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $195,791 | 3,618,000 | kWh | $0.05 |
Electricity Demand | $80,079 | 9,076 | kW-months/year | $8.82 |
Electricity Fees | $1,482 | - | $ | - |
Fuel Oil #4 | $59,137 | 9,360 | MMBtu | $6.32 |
TOTAL ENERGY COSTS | $362,595 | |||
RECOMMENDED SAVINGS* | $81,493 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $965 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | LPG | Fuel Oil #4 | Electricity Usage | Electricity Demand | LPG | Fuel Oil #4 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | MMBtu | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.1311 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT |
Savings: $46,957 Cost: $57,500 |
$78,325 | 1,442,442 | $17,872 | 2,015 | $(-49,240) | (-6,155) | - | - |
$78,325 1,442,442 kWh |
$17,872 2,015 kW-months/year |
$(-49,240) (-6,155) MMBtu |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT |
Savings: $5,668 Cost: $14,000 |
- | - | - | - | - | - | $5,668 | 1,042 |
- - kWh |
- - kW-months/year |
- - MMBtu |
$5,668 1,042 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO |
Savings: $12,833 Cost: $13,000 |
- | - | - | - | - | - | $12,833 | 2,359 |
- - kWh |
- - kW-months/year |
- - MMBtu |
$12,833 2,359 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $12,423 Cost: $7,500 |
$4,546 | 9,486 | - | - | - | - | $7,877 | 1,448 |
$4,546 9,486 kWh |
- - kW-months/year |
- - MMBtu |
$7,877 1,448 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.1311 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT |
Savings: $1,038 Cost: $10,000 |
$2,790 | 51,383 | - | - | $(-1,752) | (-219) | - | - |
$2,790 51,383 kWh |
- - kW-months/year |
$(-1,752) (-219) MMBtu |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.1311 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT |
Savings: $911 Cost: $6,000 |
$2,447 | 45,068 | - | - | $(-1,536) | (-192) | - | - |
$2,447 45,068 kWh |
- - kW-months/year |
$(-1,536) (-192) MMBtu |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $698 Cost: $12,180 |
$531 | 9,772 | $167 | 19 | - | - | - | - |
$531 9,772 kWh |
$167 19 kW-months/year |
- - MMBtu |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $508 Cost: $300 |
$508 | 9,353 | - | - | - | - | - | - |
$508 9,353 kWh |
- - kW-months/year |
- - MMBtu |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $457 Cost: $500 |
- | - | - | - | - | - | $457 | 84 |
- - kWh |
- - kW-months/year |
- - MMBtu |
$457 84 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $81,493 Cost: $120,980 |
$89,147 | 1,567,504 | $18,039 | 2,034 | $(-52,528) | (-6,566) | $26,835 | 4,933 | $89,147 1,567,504 kWh |
$18,039 2,034 kW-months/year |
$(-52,528) (-6,566) MMBtu |
$26,835 4,933 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $965 Cost: $800 |
$508 | 9,353 | - | - | - | - | $457 | 84 | $508 9,353 kWh |
- - kW-months/year |
- - MMBtu |
$457 84 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | MMBtu | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | LPG | Fuel Oil #4 | Electricity Usage | Electricity Demand | LPG | Fuel Oil #4 |