Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Massachusetts |
---|---|
Assessment Year | 2002 |
Principal Product | Specialty Papers and boards |
NAICS | n/a |
SIC | 2631 - Paperboard Mills |
Sales | $10,000,000-$50,000,000 |
# of Employees | 60 |
Plant Area (Sq.Ft.) | 52,000 |
Annual Production | 1,400,000 Pounds |
Production Hrs. Annual | 6,240 |
Location (State) | NH |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $161,408 | 2,062,200 | kWh | $0.08 |
Electricity Demand | $54,840 | 8,272 | kW-months/year | $6.63 |
Electricity Fees | $1,260 | - | $ | - |
Natural Gas | $56,442 | 5,690 | MMBtu | $9.92 |
Fuel Oil #6 | $119,800 | 22,468 | MMBtu | $5.33 |
TOTAL ENERGY COSTS | $393,750 | |||
RECOMMENDED SAVINGS* | $32,858 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $8,164 |
#|Description |
Savings Cost |
Status | Electricity Usage | Natural Gas | Fuel Oil #6 | Administrative Changes | Electricity Usage | Natural Gas | Fuel Oil #6 | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | MMBtu | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.5111 CONVERT FROM INDIRECT TO DIRECT FIRED SYSTEMS |
Savings: $16,518 Cost: $13,775 |
- | - | $14,496 | 2,154 | $2,022 | 512 | - | - |
- - kWh |
$14,496 2,154 MMBtu |
$2,022 512 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.2443 RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR |
Savings: $5,976 Cost: $7,800 |
- | - | $5,976 | 888 | - | - | - | - |
- - kWh |
$5,976 888 MMBtu |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.8112 COMBINE UTILITY METERS |
Savings: $2,200 Cost: $6,470 |
- | - | - | - | - | - | $2,200 | - |
- - kWh |
- - MMBtu |
- - MMBtu |
$2,200 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.5123 REDUCE FLUID FLOW RATES |
Savings: $1,849 Cost: - |
$1,849 | 23,705 | - | - | - | - | - | - |
$1,849 23,705 kWh |
- - MMBtu |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7132 INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS |
Savings: $1,619 Cost: - |
$1,619 | 20,757 | - | - | - | - | - | - |
$1,619 20,757 kWh |
- - MMBtu |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.2122 INSTALL / REPAIR INSULATION ON CONDENSATE LINES |
Savings: $1,604 Cost: $1,792 |
- | - | - | - | $1,604 | 427 | - | - |
- - kWh |
- - MMBtu |
$1,604 427 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4322 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES |
Savings: $1,382 Cost: - |
- | - | - | - | $1,382 | 350 | - | - |
- - kWh |
- - MMBtu |
$1,382 350 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.2163 USE MINIMUM STEAM OPERATING PRESSURE |
Savings: $960 Cost: - |
- | - | - | - | $960 | 243 | - | - |
- - kWh |
- - MMBtu |
$960 243 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.7221 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA |
Savings: $750 Cost: - |
- | - | - | - | $750 | 190 | - | - |
- - kWh |
- - MMBtu |
$750 190 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $32,858 Cost: $29,837 |
$3,468 | 44,462 | $20,472 | 3,042 | $6,718 | 1,722 | $2,200 | - | $3,468 44,462 kWh |
$20,472 3,042 MMBtu |
$6,718 1,722 MMBtu |
$2,200 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $8,164 Cost: $1,792 |
$3,468 | 44,462 | - | - | $4,696 | 1,210 | - | - | $3,468 44,462 kWh |
- - MMBtu |
$4,696 1,210 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | MMBtu | $ | MMBtu | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Natural Gas | Fuel Oil #6 | Administrative Changes | Electricity Usage | Natural Gas | Fuel Oil #6 | Administrative Changes |