Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Massachusetts |
---|---|
Assessment Year | 2003 |
Principal Product | PET containers |
NAICS | 326160 - Plastics Bottle Manufacturing |
SIC | 3085 - Plastics Bottles |
Sales | $50,000,000-$100,000,000 |
# of Employees | 26 |
Plant Area (Sq.Ft.) | 215,000 |
Annual Production | 808,000,000 Pieces |
Production Hrs. Annual | 8,712 |
Location (State) | NH |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $1,904,613 | 26,085,221 | kWh | $0.07 |
Electricity Demand | $310,166 | 44,726 | kW-months/year | $6.93 |
Electricity Fees | $12,064 | - | $ | - |
Natural Gas | $17,044 | 2,028 | MMBtu | $8.40 |
TOTAL ENERGY COSTS | $2,243,887 | |||
RECOMMENDED SAVINGS* | $81,911 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $4,979 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Primary Raw Material | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Primary Raw Material | One-time Revenue or Avoided Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $28,705 Cost: $21,900 |
$24,131 | 357,500 | $4,574 | 660 | - | - | - | - | - | - | - | - |
$24,131 357,500 kWh |
$4,574 660 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.2612 USE COOLING TOWER WATER INSTEAD OF REFRIGERATION |
Savings: $26,717 Cost: $40,000 |
$26,717 | 395,800 | - | - | - | - | - | - | - | - | - | - |
$26,717 395,800 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.3131 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS |
Savings: $12,265 Cost: - |
- | - | $8,413 | 1,214 | - | - | $3,120 | - | - | - | $732 | - |
- - kWh |
$8,413 1,214 kW-months/year |
- - MMBtu |
$3,120 - $ |
- - $ |
$732 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.2623 MINIMIZE CONDENSER COOLING WATER TEMPERATURE |
Savings: $5,292 Cost: - |
$5,292 | 78,400 | - | - | - | - | - | - | - | - | - | - |
$5,292 78,400 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.3132 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS |
Savings: $3,953 Cost: $12,400 |
- | - | $3,250 | 1,406 | - | - | - | - | $703 | - | - | - |
- - kWh |
$3,250 1,406 kW-months/year |
- - MMBtu |
- - $ |
$703 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7243 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS |
Savings: $3,571 Cost: $12,104 |
$(-1,067) | (-15,800) | $(-132) | (-19) | $4,770 | 610 | - | - | - | - | - | - |
$(-1,067) (-15,800) kWh |
$(-132) (-19) kW-months/year |
$4,770 610 MMBtu |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7224 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS |
Savings: $1,408 Cost: $527 |
$470 | 7,200 | - | - | $938 | 120 | - | - | - | - | - | - |
$470 7,200 kWh |
- - kW-months/year |
$938 120 MMBtu |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $81,911 Cost: $86,931 |
$55,543 | 823,100 | $16,105 | 3,261 | $5,708 | 730 | $3,120 | - | $703 | - | $732 | - | $55,543 823,100 kWh |
$16,105 3,261 kW-months/year |
$5,708 730 MMBtu |
$3,120 - $ |
$703 - $ |
$732 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $4,979 Cost: $12,631 |
$(-597) | (-8,600) | $(-132) | (-19) | $5,708 | 730 | - | - | - | - | - | - | $(-597) (-8,600) kWh |
$(-132) (-19) kW-months/year |
$5,708 730 MMBtu |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Primary Raw Material | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Primary Raw Material | One-time Revenue or Avoided Cost |