Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Massachusetts |
---|---|
Assessment Year | 2004 |
Principal Product | Recycled tissue paper |
NAICS | 322121 - Paper (except Newsprint) Mills |
SIC | 2621 - Paper Mills |
Sales | $10,000,000-$50,000,000 |
# of Employees | 54 |
Plant Area (Sq.Ft.) | 50,000 |
Annual Production | 25,000 Tons |
Production Hrs. Annual | 8,640 |
Location (State) | VT |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $841,943 | 15,505,000 | kWh | $0.05 |
Electricity Demand | $388,737 | 48,801 | kW-months/year | $7.97 |
Electricity Fees | $31,982 | - | $ | - |
Fuel Oil #6 | $1,032,051 | 225,424 | MMBtu | $4.58 |
TOTAL ENERGY COSTS | $2,294,713 | |||
RECOMMENDED SAVINGS* | $160,228 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $85,433 |
#|Description |
Savings Cost |
Status | Electricity Usage | Fuel Oil #6 | Personnel Changes | Administrative Changes | Electricity Usage | Fuel Oil #6 | Personnel Changes | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | MMBtu | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 3.6112 USE FILTER AND DRYING OVEN TO REDUCE SLUDGE VOLUME |
Savings: $70,900 Cost: $270,000 |
$(-3,500) | (-65,350) | - | - | - | - | $74,400 | - |
$(-3,500) (-65,350) kWh |
- - MMBtu |
- - $ |
$74,400 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $61,633 Cost: $54,474 |
- | - | $61,633 | 13,850 | - | - | - | - |
- - kWh |
$61,633 13,850 MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $9,220 Cost: $11,950 |
$9,220 | 169,800 | - | - | - | - | - | - |
$9,220 169,800 kWh |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 4.111 ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK |
Savings: $8,762 Cost: $1,000 |
- | - | - | - | $8,762 | - | - | - |
- - kWh |
- - MMBtu |
$8,762 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $4,156 Cost: $6,867 |
- | - | $4,156 | 934 | - | - | - | - |
- - kWh |
$4,156 934 MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4131 SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY |
Savings: $3,942 Cost: $5,000 |
$3,942 | 72,600 | - | - | - | - | - | - |
$3,942 72,600 kWh |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $1,615 Cost: $1,369 |
- | - | $1,615 | 363 | - | - | - | - |
- - kWh |
$1,615 363 MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $160,228 Cost: $350,660 |
$9,662 | 177,050 | $67,404 | 15,147 | $8,762 | - | $74,400 | - | $9,662 177,050 kWh |
$67,404 15,147 MMBtu |
$8,762 - $ |
$74,400 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $85,433 Cost: $279,236 |
$(-3,500) | (-65,350) | $5,771 | 1,297 | $8,762 | - | $74,400 | - | $(-3,500) (-65,350) kWh |
$5,771 1,297 MMBtu |
$8,762 - $ |
$74,400 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | MMBtu | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Fuel Oil #6 | Personnel Changes | Administrative Changes | Electricity Usage | Fuel Oil #6 | Personnel Changes | Administrative Changes |