Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Massachusetts |
---|---|
Assessment Year | 2007 |
Principal Product | Automotive timing chains |
NAICS | 333613 - Mechanical Power Transmission Equipment Manufacturing |
SIC | 3568 - Power Transmission Equipment, Nec |
Sales | $50,000,000-$100,000,000 |
# of Employees | 195 |
Plant Area (Sq.Ft.) | 230,000 |
Annual Production | 4,000,000 Pounds |
Production Hrs. Annual | 7,488 |
Location (State) | MA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $534,502 | 8,764,800 | kWh | $0.06 |
Electricity Demand | $124,164 | 18,766 | kW-months/year | $6.62 |
Natural Gas | $102,828 | 8,823 | MMBtu | $11.65 |
LPG | $84,537 | 6,159 | MMBtu | $13.73 |
TOTAL ENERGY COSTS | $846,031 | |||
RECOMMENDED SAVINGS* | $87,872 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $5,603 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Electricity Usage | Electricity Demand | Natural Gas | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $21,636 Cost: $132,834 |
$19,183 | 231,117 | $2,453 | 370 | - | - |
$19,183 231,117 kWh |
$2,453 370 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $6,128 Cost: $3,725 |
$5,438 | 64,742 | $690 | 104 | - | - |
$5,438 64,742 kWh |
$690 104 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $5,603 Cost: $2,550 |
$4,973 | 59,200 | $630 | 95 | - | - |
$4,973 59,200 kWh |
$630 95 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $37,450 Cost: $12,998 |
- | - | - | - | $37,450 | 2,345 |
- - kWh |
- - kW-months/year |
$37,450 2,345 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS |
Savings: $16,346 Cost: $1,088 |
$2,484 | 29,573 | - | - | $13,862 | 868 |
$2,484 29,573 kWh |
- - kW-months/year |
$13,862 868 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4323 USE OPTIMUM SIZE AND CAPACITY EQUIPMENT |
Savings: $709 Cost: $300 |
$629 | 7,488 | $80 | 12 | - | - |
$629 7,488 kWh |
$80 12 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $87,872 Cost: $153,495 |
$32,707 | 392,120 | $3,853 | 581 | $51,312 | 3,213 | $32,707 392,120 kWh |
$3,853 581 kW-months/year |
$51,312 3,213 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $5,603 Cost: $2,550 |
$4,973 | 59,200 | $630 | 95 | - | - | $4,973 59,200 kWh |
$630 95 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Electricity Usage | Electricity Demand | Natural Gas |