Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Massachusetts |
---|---|
Assessment Year | 2008 |
Principal Product | Semiconductors |
NAICS | 334413 - Semiconductor and Related Device Manufacturing |
SIC | 3674 - Semiconductors And Related Devices |
Sales | $50,000,000-$100,000,000 |
# of Employees | 437 |
Plant Area (Sq.Ft.) | 160,000 |
Annual Production | 100,000,000 Pieces |
Production Hrs. Annual | 5,228 |
Location (State) | MA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $1,725,540 | 13,025,400 | kWh | $0.13 |
Electricity Demand | $178,335 | 29,430 | kW-months/year | $6.06 |
Electricity Fees | $840 | - | $ | - |
Natural Gas | $222,698 | 18,335 | MMBtu | $12.15 |
TOTAL ENERGY COSTS | $2,127,413 | |||
RECOMMENDED SAVINGS* | $67,869 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $52,019 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7314 REDUCE VENTILATION AIR |
Savings: $36,692 Cost: $39,000 |
$25,587 | 198,015 | - | - | $11,105 | 914 | - | - |
$25,587 198,015 kWh |
- - kW-months/year |
$11,105 914 MMBtu |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $11,811 Cost: $11,850 |
- | - | $11,811 | 1,755 | - | - | - | - |
- - kWh |
$11,811 1,755 kW-months/year |
- - MMBtu |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.2614 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING |
Savings: $11,640 Cost: $43,000 |
$11,640 | 87,842 | - | - | - | - | - | - |
$11,640 87,842 kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 3.4151 MINIMIZE WATER USAGE |
Savings: $4,210 Cost: $18,000 |
- | - | - | - | - | - | $4,210 | 630,000 |
- - kWh |
- - kW-months/year |
- - MMBtu |
$4,210 630,000 Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS |
Savings: $1,895 Cost: $3,000 |
- | - | - | - | $1,895 | 156 | - | - |
- - kWh |
- - kW-months/year |
$1,895 156 MMBtu |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $977 Cost: - |
$876 | 6,610 | $101 | 15 | - | - | - | - |
$876 6,610 kWh |
$101 15 kW-months/year |
- - MMBtu |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.2136 INSTALL / REPAIR INSULATION ON STEAM LINES |
Savings: $644 Cost: $689 |
- | - | - | - | $644 | 53 | - | - |
- - kWh |
- - kW-months/year |
$644 53 MMBtu |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $67,869 Cost: $115,539 |
$38,103 | 292,467 | $11,912 | 1,770 | $13,644 | 1,123 | $4,210 | 630,000 | $38,103 292,467 kWh |
$11,912 1,770 kW-months/year |
$13,644 1,123 MMBtu |
$4,210 630,000 Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $52,019 Cost: $54,539 |
$26,463 | 204,625 | $11,912 | 1,770 | $13,644 | 1,123 | - | - | $26,463 204,625 kWh |
$11,912 1,770 kW-months/year |
$13,644 1,123 MMBtu |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal |