Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Massachusetts |
---|---|
Assessment Year | 2017 |
Principal Product | Precast concrete |
NAICS | 327390 - Other Concrete Product Manufacturing |
SIC | 3272 - Concrete Products, Nec |
Sales | $100,000,000-$500,000,000 |
# of Employees | 425 |
Plant Area (Sq.Ft.) | 100,000 |
Annual Production | 66,300 Units |
Production Hrs. Annual | 5,890 |
Location (State) | MA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $90,463 | 790,911 | kWh | $0.11 |
Electricity Demand | $19,851 | 2,006 | kW-months/year | $9.90 |
Electricity Fees | $4,260 | - | $ | - |
Natural Gas | $150,476 | 20,673 | MMBtu | $7.28 |
TOTAL ENERGY COSTS | $265,050 | |||
RECOMMENDED SAVINGS* | $81,587 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $64,601 |
#|Description |
Savings Cost |
Status | Electricity Usage | Natural Gas | Electricity Usage | Natural Gas | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | MMBtu | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.9113 USE SOLAR HEAT FOR HEAT |
Savings: $58,825 Cost: $627,522 |
$58,825 | 516,007 | - | - |
$58,825 516,007 kWh |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.1116 IMPROVE COMBUSTION CONTROL CAPABILITY |
Savings: $12,851 Cost: $21,075 |
$1,504 | 13,191 | $11,347 | 1,559 |
$1,504 13,191 kWh |
$11,347 1,559 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.2136 INSTALL / REPAIR INSULATION ON STEAM LINES |
Savings: $4,135 Cost: $27,198 |
- | - | $4,135 | 568 |
- - kWh |
$4,135 568 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.2136 INSTALL / REPAIR INSULATION ON STEAM LINES |
Savings: $2,868 Cost: $652 |
- | - | $2,868 | 394 |
- - kWh |
$2,868 394 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7316 CENTRALIZE CONTROL OF EXHAUST FANS TO ENSURE THEIR SHUTDOWN, OR ESTABLISH PROGRAM TO ENSURE MANUAL SHUTDOWN |
Savings: $2,908 Cost: $1,775 |
$2,908 | 25,506 | - | - |
$2,908 25,506 kWh |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $81,587 Cost: $678,222 |
$63,237 | 554,704 | $18,350 | 2,521 | $63,237 554,704 kWh |
$18,350 2,521 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $64,601 Cost: $629,949 |
$61,733 | 541,513 | $2,868 | 394 | $61,733 541,513 kWh |
$2,868 394 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | MMBtu | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Natural Gas | Electricity Usage | Natural Gas |