IAC logo
IAC Assessment: MA0826
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: MA0826
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Massachusetts
Assessment Year 2021
Principal Product Printed circuit boards
NAICS 334412 - Bare Printed Circuit Board Manufacturing
SIC 3672 - Printed Circuit Boards
Sales $1,000,000-$5,000,000
# of Employees 20
Plant Area (Sq.Ft.) 27,000
Annual Production 50,400 Pounds
Production Hrs. Annual 2,185
Location (State) NH
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $121,861 1,078,800 kWh $0.11
Electricity Demand $70,282 5,294 kW-months/year $13.28
Electricity Fees $5,151 - $ -
Natural Gas $5,490 377 MMBtu $14.56
TOTAL ENERGY COSTS $220,013
RECOMMENDED SAVINGS* $37,374 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $1,530
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Water Usage Ancillary Material Cost Electricity Usage Electricity Demand Water Usage Ancillary Material Cost
$ kWh $ kW-months/year $ Tgal $ $
01: 3.3122 USE FILTRATION, CENTRIFUGING TO REMOVE CONTAMINANTS Savings:
$27,883
Cost:
$250,000
$(-2,725) (-24,119) $(-996) (-75) $24,774 2,900 $6,830 - $(-2,725)
(-24,119)
kWh
$(-996)
(-75)
kW-months/year
$24,774
2,900
Tgal
$6,830
-
$
02: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$4,639
Cost:
$14,650
$4,639 41,053 - - - - - - $4,639
41,053
kWh
-
-
kW-months/year
-
-
Tgal
-
-
$
03: 2.2614 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING Savings:
$2,447
Cost:
$10,800
$1,332 11,791 $1,115 84 - - - - $1,332
11,791
kWh
$1,115
84
kW-months/year
-
-
Tgal
-
-
$
04: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$979
Cost:
$1,631
$979 8,664 - - - - - - $979
8,664
kWh
-
-
kW-months/year
-
-
Tgal
-
-
$
05: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE Savings:
$552
Cost:
$250
$552 4,881 - - - - - - $552
4,881
kWh
-
-
kW-months/year
-
-
Tgal
-
-
$
06: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$551
Cost:
$1,450
$551 4,877 - - - - - - $551
4,877
kWh
-
-
kW-months/year
-
-
Tgal
-
-
$
07: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE Savings:
$323
Cost:
$625
$323 2,859 - - - - - - $323
2,859
kWh
-
-
kW-months/year
-
-
Tgal
-
-
$
TOTAL RECOMMENDED Savings:
$37,374
Cost:
$279,406
$5,651 50,006 $119 9 $24,774 2,900 $6,830 - $5,651
50,006
kWh
$119
9
kW-months/year
$24,774
2,900
Tgal
$6,830
-
$
TOTAL IMPLEMENTED Savings:
$1,530
Cost:
$3,081
$1,530 13,541 - - - - - - $1,530
13,541
kWh
-
-
kW-months/year
-
-
Tgal
-
-
$
Savings
Cost
$ kWh $ kW-months/year $ Tgal $ $
Electricity Usage Electricity Demand Water Usage Ancillary Material Cost Electricity Usage Electricity Demand Water Usage Ancillary Material Cost