Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Massachusetts
Assessment Year 2012
Principal Product Circuit board laminaiton
NAICS 334418 - Printed Circuit Assembly (Electronic Assembly) Manufacturing
SIC 3679 - Electronic Components, Nec
Sales $50,000,000-$100,000,000
# of Employees 110
Plant Area (Sq.Ft.) 60,000
Annual Production 2,628 Thousand Feet
Production Hrs. Annual 7,488
Location (State) CT
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $568,764 7,271,424 kWh $0.08
Electricity Demand $192,578 17,734 kW-months/year $10.86
Electricity Fees $10,250 - $ -
Fuel Oil #4 $177,328 7,771 MMBtu $22.82
TOTAL ENERGY COSTS $948,920
RECOMMENDED SAVINGS* $71,446 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $45,396
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Electricity Usage Electricity Demand
$ kWh $ kW-months/year
01: 2.2612 USE COOLING TOWER WATER INSTEAD OF REFRIGERATION Savings:
$37,819
Cost:
$31,800
$31,772 406,289 $6,047 557 $31,772
406,289
kWh
$6,047
557
kW-months/year
02: 2.7314 REDUCE VENTILATION AIR Savings:
$22,269
Cost:
$9,650
$18,218 232,970 $4,051 373 $18,218
232,970
kWh
$4,051
373
kW-months/year
03: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE Savings:
$4,815
Cost:
$4,000
$4,815 61,568 - - $4,815
61,568
kWh
-
-
kW-months/year
04: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT Savings:
$3,781
Cost:
-
$3,781 48,355 - - $3,781
48,355
kWh
-
-
kW-months/year
05: 2.2612 USE COOLING TOWER WATER INSTEAD OF REFRIGERATION Savings:
$2,762
Cost:
$5,000
$2,762 35,322 - - $2,762
35,322
kWh
-
-
kW-months/year
TOTAL RECOMMENDED Savings:
$71,446
Cost:
$50,450
$61,348 784,504 $10,098 930 $61,348
784,504
kWh
$10,098
930
kW-months/year
TOTAL IMPLEMENTED Savings:
$45,396
Cost:
$40,800
$39,349 503,179 $6,047 557 $39,349
503,179
kWh
$6,047
557
kW-months/year
Savings
Cost
$ kWh $ kW-months/year
Electricity Usage Electricity Demand Electricity Usage Electricity Demand