IAC logo
IAC Assessment: ME0206
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: ME0206
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Maine
Assessment Year 1997
Principal Product childrens sleepware
NAICS n/a
SIC 2361 - Girls', Children's, and Infants' Dresses, Blouses, and Shirts
Sales $10,000,000-$50,000,000
# of Employees 140
Plant Area (Sq.Ft.) 112,000
Annual Production 2,040,000 Pieces
Production Hrs. Annual 2,000
Location (State) ME
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $64,428 891,559 kWh $0.07
Electricity Demand $37,142 4,201 kW-months/year $8.84
Electricity Fees $2,360 - $ -
Fuel Oil #2 $20,511 5,069 MMBtu $4.05
TOTAL ENERGY COSTS $124,441
RECOMMENDED SAVINGS* $25,148 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Fuel Oil #2 Electricity Usage Electricity Demand Fuel Oil #2
$ kWh $ kW-months/year $ MMBtu
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$21,295
Cost:
$52,234
$12,926 215,416 $8,369 947 - - $12,926
215,416
kWh
$8,369
947
kW-months/year
-
-
MMBtu
02: 2.1311 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT Savings:
$2,622
Cost:
$2,500
$1,072 17,878 $1,887 214 $(-337) (-76) $1,072
17,878
kWh
$1,887
214
kW-months/year
$(-337)
(-76)
MMBtu
03: 2.6211 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES Savings:
$378
Cost:
$100
$378 6,448 - - - - $378
6,448
kWh
-
-
kW-months/year
-
-
MMBtu
04: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT Savings:
$367
Cost:
$150
- - - - $367 84 -
-
kWh
-
-
kW-months/year
$367
84
MMBtu
05: 2.2531 RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR Savings:
$306
Cost:
$71
- - - - $306 70 -
-
kWh
-
-
kW-months/year
$306
70
MMBtu
06: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$180
Cost:
$200
$180 2,931 - - - - $180
2,931
kWh
-
-
kW-months/year
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$25,148
Cost:
$55,255
$14,556 242,673 $10,256 1,161 $336 78 $14,556
242,673
kWh
$10,256
1,161
kW-months/year
$336
78
MMBtu
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - - - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
Savings
Cost
$ kWh $ kW-months/year $ MMBtu
Electricity Usage Electricity Demand Fuel Oil #2 Electricity Usage Electricity Demand Fuel Oil #2