Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Maine |
---|---|
Assessment Year | 1997 |
Principal Product | Garment Labels |
NAICS | n/a |
SIC | 2241 - Narrow Fabric Mills |
Sales | $5,000,000-$10,000,000 |
# of Employees | 97 |
Plant Area (Sq.Ft.) | 24,000 |
Annual Production | 338 Pieces |
Production Hrs. Annual | 8,700 |
Location (State) | ME |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $120,667 | 1,662,075 | kWh | $0.07 |
Electricity Demand | $33,114 | 3,943 | kW-months/year | $8.40 |
Electricity Fees | $1,029 | - | $ | - |
Fuel Oil #2 | $10,329 | 1,365 | MMBtu | $7.57 |
TOTAL ENERGY COSTS | $173,233 | |||
RECOMMENDED SAVINGS* | $94,643 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $65,963 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Fuel Oil #2 | Other Liquid (non-haz) | Solid Waste (non-haz) | Personnel Changes | Administrative Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Fuel Oil #2 | Other Liquid (non-haz) | Solid Waste (non-haz) | Personnel Changes | Administrative Changes | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | MMBtu | $ | gal | $ | lb | $ | $ | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 4.441 INSTALL AUTOMATIC PACKING EQUIPMENT |
Savings: $54,750 Cost: $10,120 |
- | - | - | - | - | - | - | - | - | - | - | - | $54,750 | - | - | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - MMBtu |
- - gal |
- - lb |
$54,750 - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.1311 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT |
Savings: $9,110 Cost: $20,420 |
$12,016 | 171,161 | $1,196 | 237 | $(-4,102) | (-586) | - | - | - | - | - | - | - | - | - | - | - | - |
$12,016 171,161 kWh |
$1,196 237 kW-months/year |
$(-4,102) (-586) MMBtu |
- - MMBtu |
- - gal |
- - lb |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $10,379 Cost: $15,318 |
$8,659 | 123,681 | $1,720 | 212 | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
$8,659 123,681 kWh |
$1,720 212 kW-months/year |
- - MMBtu |
- - MMBtu |
- - gal |
- - lb |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.2515 USE OPTIMUM THICKNESS INSULATION |
Savings: $2,188 Cost: $1,640 |
- | - | - | - | - | - | $2,188 | 289 | - | - | - | - | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$2,188 289 MMBtu |
- - gal |
- - lb |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $2,711 Cost: $3,950 |
$1,653 | 23,740 | $1,058 | 252 | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
$1,653 23,740 kWh |
$1,058 252 kW-months/year |
- - MMBtu |
- - MMBtu |
- - gal |
- - lb |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 4.652 REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES |
Savings: $11,213 Cost: $1,400 |
- | - | - | - | - | - | - | - | - | - | $37 | 1,840 | - | - | - | - | $11,176 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - MMBtu |
- - gal |
$37 1,840 lb |
- - $ |
- - $ |
$11,176 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 3.5313 INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE |
Savings: $3,300 Cost: - |
- | - | - | - | - | - | - | - | - | - | $3,300 | 22,000 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - MMBtu |
- - gal |
$3,300 22,000 lb |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 3.5313 INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE |
Savings: $580 Cost: $1,840 |
- | - | - | - | - | - | - | - | - | - | $180 | 1,200 | - | - | $400 | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - MMBtu |
- - gal |
$180 1,200 lb |
- - $ |
$400 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 3.4151 MINIMIZE WATER USAGE |
Savings: $412 Cost: - |
$(-46) | (-586) | - | - | - | - | - | - | $458 | 145,725 | - | - | - | - | - | - | - | - |
$(-46) (-586) kWh |
- - kW-months/year |
- - MMBtu |
- - MMBtu |
$458 145,725 gal |
- - lb |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $94,643 Cost: $54,688 |
$22,282 | 317,996 | $3,974 | 701 | $(-4,102) | (-586) | $2,188 | 289 | $458 | 145,725 | $3,517 | 25,040 | $54,750 | - | $400 | - | $11,176 | - | $22,282 317,996 kWh |
$3,974 701 kW-months/year |
$(-4,102) (-586) MMBtu |
$2,188 289 MMBtu |
$458 145,725 gal |
$3,517 25,040 lb |
$54,750 - $ |
$400 - $ |
$11,176 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $65,963 Cost: $11,520 |
- | - | - | - | - | - | - | - | - | - | $37 | 1,840 | $54,750 | - | - | - | $11,176 | - | - - kWh |
- - kW-months/year |
- - MMBtu |
- - MMBtu |
- - gal |
$37 1,840 lb |
$54,750 - $ |
- - $ |
$11,176 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | MMBtu | $ | gal | $ | lb | $ | $ | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Fuel Oil #2 | Other Liquid (non-haz) | Solid Waste (non-haz) | Personnel Changes | Administrative Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Fuel Oil #2 | Other Liquid (non-haz) | Solid Waste (non-haz) | Personnel Changes | Administrative Changes | Ancillary Material Cost |