Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Maine |
---|---|
Assessment Year | 1997 |
Principal Product | snowplows |
NAICS | n/a |
SIC | 3531 - Construction Machinery |
Sales | $50,000,000-$100,000,000 |
# of Employees | 200 |
Plant Area (Sq.Ft.) | 83,145 |
Annual Production | 19,000 Pieces |
Production Hrs. Annual | 5,330 |
Location (State) | ME |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $220,639 | 3,018,757 | kWh | $0.07 |
Electricity Demand | $87,095 | 8,827 | kW-months/year | $9.87 |
Electricity Fees | $6,054 | - | $ | - |
LPG | $218,840 | 29,638 | MMBtu | $7.38 |
Fuel Oil #2 | $19,163 | 2,831 | MMBtu | $6.77 |
TOTAL ENERGY COSTS | $551,791 | |||
RECOMMENDED SAVINGS* | $21,882 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | LPG | Administrative Changes | Electricity Usage | Electricity Demand | LPG | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $8,462 Cost: $33,192 |
$5,813 | 82,943 | $2,649 | 267 | - | - | - | - |
$5,813 82,943 kWh |
$2,649 267 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.2424 USE HEAT IN FLUE GASES TO PREHEAT PRODUCTS OR MATERIALS |
Savings: $8,031 Cost: $17,000 |
- | - | - | - | $8,031 | 2,111 | - | - |
- - kWh |
- - kW-months/year |
$8,031 2,111 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $1,827 Cost: $2,398 |
$1,827 | 26,084 | - | - | - | - | - | - |
$1,827 26,084 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7314 REDUCE VENTILATION AIR |
Savings: $1,803 Cost: $6,000 |
- | - | - | - | $1,803 | 261 | - | - |
- - kWh |
- - kW-months/year |
$1,803 261 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $883 Cost: $250 |
$883 | 12,603 | - | - | - | - | - | - |
$883 12,603 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 4.231 PURCHASE EQUIPMENT INSTEAD OF LEASING |
Savings: $561 Cost: $1,283 |
- | - | - | - | - | - | $561 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$561 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $315 Cost: $264 |
- | - | - | - | $315 | 46 | - | - |
- - kWh |
- - kW-months/year |
$315 46 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $21,882 Cost: $60,387 |
$8,523 | 121,630 | $2,649 | 267 | $10,149 | 2,418 | $561 | - | $8,523 121,630 kWh |
$2,649 267 kW-months/year |
$10,149 2,418 MMBtu |
$561 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | LPG | Administrative Changes | Electricity Usage | Electricity Demand | LPG | Administrative Changes |