Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Maine |
---|---|
Assessment Year | 1998 |
Principal Product | storage and retrieval systems |
NAICS | n/a |
SIC | 3535 - Conveyors And Conveying Equipment |
Sales | $5,000,000-$10,000,000 |
# of Employees | 60 |
Plant Area (Sq.Ft.) | 48,000 |
Annual Production | 1,000,000 Pounds |
Production Hrs. Annual | 2,210 |
Location (State) | ME |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $39,025 | 535,756 | kWh | $0.07 |
Electricity Demand | $17,154 | 2,030 | kW-months/year | $8.45 |
Electricity Fees | $4,032 | - | $ | - |
Natural Gas | $23,289 | 3,182 | MMBtu | $7.32 |
TOTAL ENERGY COSTS | $89,187 | |||
RECOMMENDED SAVINGS* | $19,553 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $19,161 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Other Liquid (haz) | Administrative Changes | Electricity Usage | Electricity Demand | Natural Gas | Other Liquid (haz) | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | gal | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.1311 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT |
Savings: $3,934 Cost: $2,500 |
$4,019 | 69,754 | $304 | 36 | $(-389) | (-53) | - | - | - | - |
$4,019 69,754 kWh |
$304 36 kW-months/year |
$(-389) (-53) MMBtu |
- - gal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $3,602 Cost: $11,858 |
$2,637 | 37,808 | $965 | 114 | - | - | - | - | - | - |
$2,637 37,808 kWh |
$965 114 kW-months/year |
- - MMBtu |
- - gal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.2443 RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR |
Savings: $2,513 Cost: $8,600 |
- | - | - | - | $2,513 | 343 | - | - | - | - |
- - kWh |
- - kW-months/year |
$2,513 343 MMBtu |
- - gal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.8121 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES |
Savings: $2,383 Cost: - |
- | - | - | - | - | - | - | - | $2,383 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - gal |
$2,383 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.2515 USE OPTIMUM THICKNESS INSULATION |
Savings: $1,126 Cost: $1,700 |
- | - | - | - | $1,126 | 123 | - | - | - | - |
- - kWh |
- - kW-months/year |
$1,126 123 MMBtu |
- - gal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.1311 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT |
Savings: $591 Cost: $2,260 |
$245 | 3,517 | $456 | 54 | $(-110) | (-15) | - | - | - | - |
$245 3,517 kWh |
$456 54 kW-months/year |
$(-110) (-15) MMBtu |
- - gal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.2515 USE OPTIMUM THICKNESS INSULATION |
Savings: $392 Cost: $90 |
$392 | 5,862 | - | - | - | - | - | - | - | - |
$392 5,862 kWh |
- - kW-months/year |
- - MMBtu |
- - gal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.2515 USE OPTIMUM THICKNESS INSULATION |
Savings: $90 Cost: $160 |
- | - | - | - | $90 | 12 | - | - | - | - |
- - kWh |
- - kW-months/year |
$90 12 MMBtu |
- - gal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 3.2123 CONVERT TO HIGH VOLUME LOW PRESSURE (HVLP) PAINT GUNS |
Savings: $4,922 Cost: $3,036 |
- | - | - | - | - | - | $4,922 | 984 | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$4,922 984 gal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $19,553 Cost: $30,204 |
$7,293 | 116,941 | $1,725 | 204 | $3,230 | 410 | $4,922 | 984 | $2,383 | - | $7,293 116,941 kWh |
$1,725 204 kW-months/year |
$3,230 410 MMBtu |
$4,922 984 gal |
$2,383 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $19,161 Cost: $30,114 |
$6,901 | 111,079 | $1,725 | 204 | $3,230 | 410 | $4,922 | 984 | $2,383 | - | $6,901 111,079 kWh |
$1,725 204 kW-months/year |
$3,230 410 MMBtu |
$4,922 984 gal |
$2,383 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | gal | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Other Liquid (haz) | Administrative Changes | Electricity Usage | Electricity Demand | Natural Gas | Other Liquid (haz) | Administrative Changes |