IAC logo
IAC Assessment: ME0251
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: ME0251
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Maine
Assessment Year 1998
Principal Product icecream
NAICS n/a
SIC 2024 - Ice Cream And Frozen Desserts
Sales $1,000,000-$5,000,000
# of Employees 200
Plant Area (Sq.Ft.) 33,460
Annual Production 4,500 Thousand Gallons
Production Hrs. Annual 7,200
Location (State) VT
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $288,954 6,065,944 kWh $0.05
Electricity Demand $198,892 14,499 kW-months/year $13.72
Electricity Fees $(-547) - $ -
LPG $6,115 1,020 MMBtu $6.00
Fuel Oil #2 $25,215 4,714 MMBtu $5.35
TOTAL ENERGY COSTS $518,629
RECOMMENDED SAVINGS* $168,710 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $166,070
#|Description Savings
Cost
Status Electricity Usage Fuel Oil #2 Solid Waste (non-haz) Administrative Changes Primary Raw Material Ancillary Material Cost Electricity Usage Fuel Oil #2 Solid Waste (non-haz) Administrative Changes Primary Raw Material Ancillary Material Cost
$ kWh $ MMBtu $ lb $ $ $ $ $ $
01: 2.2511 INSULATE BARE EQUIPMENT Savings:
$2,487
Cost:
$600
$2,487 16,706 - - - - - - - - - - $2,487
16,706
kWh
-
-
MMBtu
-
-
lb
-
-
$
-
-
$
-
-
$
02: 4.652 REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES Savings:
$1,440
Cost:
-
- - - - - - - - - - $1,440 - -
-
kWh
-
-
MMBtu
-
-
lb
-
-
$
-
-
$
$1,440
-
$
03: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT Savings:
$1,240
Cost:
$2,100
$1,240 14,947 - - - - - - - - - - $1,240
14,947
kWh
-
-
MMBtu
-
-
lb
-
-
$
-
-
$
-
-
$
04: 2.1113 REDUCE COMBUSTION AIR FLOW TO OPTIMUM Savings:
$1,020
Cost:
$400
- - $1,020 209 - - - - - - - - -
-
kWh
$1,020
209
MMBtu
-
-
lb
-
-
$
-
-
$
-
-
$
05: 2.8121 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES Savings:
$448
Cost:
-
- - - - - - $448 - - - - - -
-
kWh
-
-
MMBtu
-
-
lb
$448
-
$
-
-
$
-
-
$
06: 4.131 MODIFY PROCESS TO REDUCE MATERIAL USE/COST Savings:
$160,875
Cost:
$31,200
- - - - $6,435 171,600 - - $154,440 - - - -
-
kWh
-
-
MMBtu
$6,435
171,600
lb
-
-
$
$154,440
-
$
-
-
$
07: 3.5315 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER Savings:
$1,200
Cost:
$1,850
- - - - $1,200 240,000 - - - - - - -
-
kWh
-
-
MMBtu
$1,200
240,000
lb
-
-
$
-
-
$
-
-
$
TOTAL RECOMMENDED Savings:
$168,710
Cost:
$36,150
$3,727 31,653 $1,020 209 $7,635 411,600 $448 - $154,440 - $1,440 - $3,727
31,653
kWh
$1,020
209
MMBtu
$7,635
411,600
lb
$448
-
$
$154,440
-
$
$1,440
-
$
TOTAL IMPLEMENTED Savings:
$166,070
Cost:
$34,300
$3,727 31,653 $1,020 209 $6,435 171,600 $448 - $154,440 - - - $3,727
31,653
kWh
$1,020
209
MMBtu
$6,435
171,600
lb
$448
-
$
$154,440
-
$
-
-
$
Savings
Cost
$ kWh $ MMBtu $ lb $ $ $ $ $ $
Electricity Usage Fuel Oil #2 Solid Waste (non-haz) Administrative Changes Primary Raw Material Ancillary Material Cost Electricity Usage Fuel Oil #2 Solid Waste (non-haz) Administrative Changes Primary Raw Material Ancillary Material Cost