Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Maine |
---|---|
Assessment Year | 1998 |
Principal Product | glass slides |
NAICS | n/a |
SIC | 3231 - Products Of Purchased Glass |
Sales | $10,000,000-$50,000,000 |
# of Employees | 300 |
Plant Area (Sq.Ft.) | 95,000 |
Annual Production | 27,000,000 Pieces |
Production Hrs. Annual | 4,000 |
Location (State) | NH |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $330,657 | 4,549,824 | kWh | $0.07 |
Electricity Demand | $82,255 | 10,458 | kW-months/year | $7.87 |
Electricity Fees | $5,258 | - | $ | - |
Natural Gas | $46,239 | 8,230 | MMBtu | $5.62 |
LPG | $4,105 | 150 | MMBtu | $27.37 |
TOTAL ENERGY COSTS | $523,310 | |||
RECOMMENDED SAVINGS* | $79,986 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $47,993 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Administrative Changes | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 4.612 CONTRACT OUT MAINTENANCE |
Savings: $32,242 Cost: $75,900 |
$10,742 | 134,232 | - | - | - | - | - | - | $21,500 | - |
$10,742 134,232 kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
$21,500 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.1311 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT |
Savings: $11,877 Cost: $21,500 |
$13,524 | 168,816 | $2,136 | 276 | $(-3,783) | (-1,014) | - | - | - | - |
$13,524 168,816 kWh |
$2,136 276 kW-months/year |
$(-3,783) (-1,014) MMBtu |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 4.231 PURCHASE EQUIPMENT INSTEAD OF LEASING |
Savings: $3,760 Cost: $20,100 |
- | - | - | - | - | - | - | - | $3,760 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
$3,760 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $2,503 Cost: $12,300 |
$2,047 | 25,791 | $456 | 58 | - | - | - | - | - | - |
$2,047 25,791 kWh |
$456 58 kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $2,747 Cost: $7,023 |
$2,297 | 28,722 | $450 | 58 | - | - | - | - | - | - |
$2,297 28,722 kWh |
$450 58 kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 4.211 CONSIDER USE / PURCHASE OF BULK MATERIALS WHERE POSSIBLE |
Savings: $2,059 Cost: $8,900 |
- | - | - | - | - | - | - | - | $2,059 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
$2,059 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.1311 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT |
Savings: $2,060 Cost: $3,860 |
$535 | 6,741 | $1,686 | 216 | $(-161) | (-29) | - | - | - | - |
$535 6,741 kWh |
$1,686 216 kW-months/year |
$(-161) (-29) MMBtu |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $1,945 Cost: $2,860 |
$1,945 | 79,426 | - | - | - | - | - | - | - | - |
$1,945 79,426 kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 3.4111 USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION |
Savings: $11,059 Cost: $7,193 |
- | - | - | - | $4,944 | 869 | $6,115 | 1,247,130 | - | - |
- - kWh |
- - kW-months/year |
$4,944 869 MMBtu |
$6,115 1,247,130 Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 3.4111 USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION |
Savings: $9,734 Cost: $15,640 |
$(-309) | (-3,224) | - | - | $4,385 | 780 | $5,658 | 1,125,000 | - | - |
$(-309) (-3,224) kWh |
- - kW-months/year |
$4,385 780 MMBtu |
$5,658 1,125,000 Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $79,986 Cost: $175,276 |
$30,781 | 440,504 | $4,728 | 608 | $5,385 | 606 | $11,773 | 2,372,130 | $27,319 | - | $30,781 440,504 kWh |
$4,728 608 kW-months/year |
$5,385 606 MMBtu |
$11,773 2,372,130 Tgal |
$27,319 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $47,993 Cost: $92,976 |
$14,984 | 242,380 | $450 | 58 | $4,944 | 869 | $6,115 | 1,247,130 | $21,500 | - | $14,984 242,380 kWh |
$450 58 kW-months/year |
$4,944 869 MMBtu |
$6,115 1,247,130 Tgal |
$21,500 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Administrative Changes | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Administrative Changes |