IAC logo
IAC Assessment: ME0255
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: ME0255
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Maine
Assessment Year 1998
Principal Product glass slides
NAICS n/a
SIC 3231 - Products Of Purchased Glass
Sales $10,000,000-$50,000,000
# of Employees 300
Plant Area (Sq.Ft.) 95,000
Annual Production 27,000,000 Pieces
Production Hrs. Annual 4,000
Location (State) NH
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $330,657 4,549,824 kWh $0.07
Electricity Demand $82,255 10,458 kW-months/year $7.87
Electricity Fees $5,258 - $ -
Natural Gas $46,239 8,230 MMBtu $5.62
LPG $4,105 150 MMBtu $27.37
TOTAL ENERGY COSTS $523,310
RECOMMENDED SAVINGS* $79,986 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $47,993
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Water Disposal Administrative Changes Electricity Usage Electricity Demand Natural Gas Water Disposal Administrative Changes
$ kWh $ kW-months/year $ MMBtu $ Tgal $ $
01: 4.612 CONTRACT OUT MAINTENANCE Savings:
$32,242
Cost:
$75,900
$10,742 134,232 - - - - - - $21,500 - $10,742
134,232
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
Tgal
$21,500
-
$
02: 2.1311 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT Savings:
$11,877
Cost:
$21,500
$13,524 168,816 $2,136 276 $(-3,783) (-1,014) - - - - $13,524
168,816
kWh
$2,136
276
kW-months/year
$(-3,783)
(-1,014)
MMBtu
-
-
Tgal
-
-
$
03: 4.231 PURCHASE EQUIPMENT INSTEAD OF LEASING Savings:
$3,760
Cost:
$20,100
- - - - - - - - $3,760 - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
Tgal
$3,760
-
$
04: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE Savings:
$2,503
Cost:
$12,300
$2,047 25,791 $456 58 - - - - - - $2,047
25,791
kWh
$456
58
kW-months/year
-
-
MMBtu
-
-
Tgal
-
-
$
05: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS Savings:
$2,747
Cost:
$7,023
$2,297 28,722 $450 58 - - - - - - $2,297
28,722
kWh
$450
58
kW-months/year
-
-
MMBtu
-
-
Tgal
-
-
$
06: 4.211 CONSIDER USE / PURCHASE OF BULK MATERIALS WHERE POSSIBLE Savings:
$2,059
Cost:
$8,900
- - - - - - - - $2,059 - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
Tgal
$2,059
-
$
07: 2.1311 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT Savings:
$2,060
Cost:
$3,860
$535 6,741 $1,686 216 $(-161) (-29) - - - - $535
6,741
kWh
$1,686
216
kW-months/year
$(-161)
(-29)
MMBtu
-
-
Tgal
-
-
$
08: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT Savings:
$1,945
Cost:
$2,860
$1,945 79,426 - - - - - - - - $1,945
79,426
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
Tgal
-
-
$
09: 3.4111 USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION Savings:
$11,059
Cost:
$7,193
- - - - $4,944 869 $6,115 1,247,130 - - -
-
kWh
-
-
kW-months/year
$4,944
869
MMBtu
$6,115
1,247,130
Tgal
-
-
$
10: 3.4111 USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION Savings:
$9,734
Cost:
$15,640
$(-309) (-3,224) - - $4,385 780 $5,658 1,125,000 - - $(-309)
(-3,224)
kWh
-
-
kW-months/year
$4,385
780
MMBtu
$5,658
1,125,000
Tgal
-
-
$
TOTAL RECOMMENDED Savings:
$79,986
Cost:
$175,276
$30,781 440,504 $4,728 608 $5,385 606 $11,773 2,372,130 $27,319 - $30,781
440,504
kWh
$4,728
608
kW-months/year
$5,385
606
MMBtu
$11,773
2,372,130
Tgal
$27,319
-
$
TOTAL IMPLEMENTED Savings:
$47,993
Cost:
$92,976
$14,984 242,380 $450 58 $4,944 869 $6,115 1,247,130 $21,500 - $14,984
242,380
kWh
$450
58
kW-months/year
$4,944
869
MMBtu
$6,115
1,247,130
Tgal
$21,500
-
$
Savings
Cost
$ kWh $ kW-months/year $ MMBtu $ Tgal $ $
Electricity Usage Electricity Demand Natural Gas Water Disposal Administrative Changes Electricity Usage Electricity Demand Natural Gas Water Disposal Administrative Changes