Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Maine |
---|---|
Assessment Year | 1999 |
Principal Product | Electric Motors |
NAICS | n/a |
SIC | 3621 - Motors And Generators |
Sales | $10,000,000-$50,000,000 |
# of Employees | 160 |
Plant Area (Sq.Ft.) | 120,000 |
Annual Production | 190,000 Pieces |
Production Hrs. Annual | 6,000 |
Location (State) | NH |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $190,620 | 2,156,213 | kWh | $0.09 |
Electricity Demand | $52,649 | 6,710 | kW-months/year | $7.85 |
Electricity Fees | $1,481 | - | $ | - |
Natural Gas | $30,812 | 4,725 | MMBtu | $6.52 |
TOTAL ENERGY COSTS | $279,673 | |||
RECOMMENDED SAVINGS* | $62,469 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $57,555 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Primary Raw Material | Water Consumption | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Primary Raw Material | Water Consumption | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | $ | $ | Tgal | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $18,284 Cost: $80,602 |
$13,970 | 155,334 | $4,314 | 550 | - | - | - | - | - | - | - | - |
$13,970 155,334 kWh |
$4,314 550 kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.1311 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT |
Savings: $10,535 Cost: $25,000 |
$9,110 | 101,407 | $4,240 | 540 | $(-2,815) | (-432) | - | - | - | - | - | - |
$9,110 101,407 kWh |
$4,240 540 kW-months/year |
$(-2,815) (-432) MMBtu |
- - Tgal |
- - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.1311 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT |
Savings: $9,477 Cost: $7,909 |
$10,934 | 121,630 | $3,108 | 396 | $(-4,565) | (-700) | - | - | - | - | - | - |
$10,934 121,630 kWh |
$3,108 396 kW-months/year |
$(-4,565) (-700) MMBtu |
- - Tgal |
- - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $7,134 Cost: $900 |
$7,134 | 79,426 | - | - | - | - | - | - | - | - | - | - |
$7,134 79,426 kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.1311 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT |
Savings: $4,914 Cost: $11,200 |
$974 | 10,844 | $4,240 | 540 | $(-300) | (-46) | - | - | - | - | - | - |
$974 10,844 kWh |
$4,240 540 kW-months/year |
$(-300) (-46) MMBtu |
- - Tgal |
- - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4322 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES |
Savings: $4,704 Cost: $12,000 |
$3,276 | 36,049 | $1,428 | 182 | - | - | - | - | - | - | - | - |
$3,276 36,049 kWh |
$1,428 182 kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.2614 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING |
Savings: $4,394 Cost: $3,080 |
$4,394 | 48,652 | - | - | - | - | - | - | - | - | - | - |
$4,394 48,652 kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $1,053 Cost: $1,200 |
$1,053 | 11,723 | - | - | - | - | - | - | - | - | - | - |
$1,053 11,723 kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $886 Cost: $200 |
$886 | 9,965 | - | - | - | - | - | - | - | - | - | - |
$886 9,965 kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 3.4151 MINIMIZE WATER USAGE |
Savings: $788 Cost: $500 |
- | - | - | - | - | - | $485 | 120,000 | - | - | $303 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$485 120,000 Tgal |
- - $ |
$303 - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 2.4151 DEVELOP A REPAIR/REPLACE POLICY |
Savings: $271 Cost: $325 |
$190 | 1,758 | - | - | - | - | $51 | 12,500 | - | - | $30 | - |
$190 1,758 kWh |
- - kW-months/year |
- - MMBtu |
$51 12,500 Tgal |
- - $ |
$30 - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
12: 4.125 |
Savings: $29 Cost: $27 |
- | - | - | - | - | - | - | - | $29 | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
$29 - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $62,469 Cost: $142,943 |
$51,921 | 576,788 | $17,330 | 2,208 | $(-7,680) | (-1,178) | $536 | 132,500 | $29 | - | $333 | - | $51,921 576,788 kWh |
$17,330 2,208 kW-months/year |
$(-7,680) (-1,178) MMBtu |
$536 132,500 Tgal |
$29 - $ |
$333 - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $57,555 Cost: $131,743 |
$50,947 | 565,944 | $13,090 | 1,668 | $(-7,380) | (-1,132) | $536 | 132,500 | $29 | - | $333 | - | $50,947 565,944 kWh |
$13,090 1,668 kW-months/year |
$(-7,380) (-1,132) MMBtu |
$536 132,500 Tgal |
$29 - $ |
$333 - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | $ | $ | Tgal | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Primary Raw Material | Water Consumption | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Primary Raw Material | Water Consumption |