Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Maine |
---|---|
Assessment Year | 2000 |
Principal Product | Fiber Extrusion |
NAICS | n/a |
SIC | 3081 - Unsupported Plastics Film & Sheet |
Sales | $10,000,000-$50,000,000 |
# of Employees | 83 |
Plant Area (Sq.Ft.) | 45,000 |
Annual Production | 20,500,000 Pounds |
Production Hrs. Annual | 8,400 |
Location (State) | ME |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $855,458 | 9,936,987 | kWh | $0.09 |
Electricity Demand | $236,287 | 31,547 | kW-months/year | $7.49 |
LPG | $139,448 | 27,975 | MMBtu | $4.98 |
TOTAL ENERGY COSTS | $1,248,193 | |||
RECOMMENDED SAVINGS* | $101,097 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $95,156 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | LPG | Water Disposal | Electricity Usage | Electricity Demand | LPG | Water Disposal | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.1311 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT |
Savings: $80,666 Cost: $36,000 |
$97,580 | 1,394,490 | $14,740 | 1,968 | $(-31,654) | (-6,344) | - | - |
$97,580 1,394,490 kWh |
$14,740 1,968 kW-months/year |
$(-31,654) (-6,344) MMBtu |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $3,760 Cost: $8,904 |
$3,088 | 44,256 | $672 | 90 | - | - | - | - |
$3,088 44,256 kWh |
$672 90 kW-months/year |
- - MMBtu |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $2,228 Cost: $250 |
$2,228 | 31,946 | - | - | - | - | - | - |
$2,228 31,946 kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7241 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT |
Savings: $2,181 Cost: $4,360 |
$2,181 | 31,067 | - | - | - | - | - | - |
$2,181 31,067 kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 3.4151 MINIMIZE WATER USAGE |
Savings: $12,262 Cost: $1,000 |
- | - | - | - | - | - | $12,262 | 36,967 |
- - kWh |
- - kW-months/year |
- - MMBtu |
$12,262 36,967 Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $101,097 Cost: $50,514 |
$105,077 | 1,501,759 | $15,412 | 2,058 | $(-31,654) | (-6,344) | $12,262 | 36,967 | $105,077 1,501,759 kWh |
$15,412 2,058 kW-months/year |
$(-31,654) (-6,344) MMBtu |
$12,262 36,967 Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $95,156 Cost: $37,250 |
$99,808 | 1,426,436 | $14,740 | 1,968 | $(-31,654) | (-6,344) | $12,262 | 36,967 | $99,808 1,426,436 kWh |
$14,740 1,968 kW-months/year |
$(-31,654) (-6,344) MMBtu |
$12,262 36,967 Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | LPG | Water Disposal | Electricity Usage | Electricity Demand | LPG | Water Disposal |