Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Maine |
---|---|
Assessment Year | 2000 |
Principal Product | 3/4" Finished Pine Boards |
NAICS | n/a |
SIC | 2421 - Sawmills And Planing Mills, General |
Sales | $10,000,000-$50,000,000 |
# of Employees | 60 |
Plant Area (Sq.Ft.) | 115,000 |
Annual Production | 24,000,000 Thousand Feet |
Production Hrs. Annual | 3,750 |
Location (State) | ME |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $404,362 | 8,044,549 | kWh | $0.05 |
Electricity Demand | $133,181 | 42,201 | kW-months/year | $3.16 |
Electricity Fees | $16,030 | - | $ | - |
Fuel Oil #2 | $504,320 | 96,399 | MMBtu | $5.23 |
TOTAL ENERGY COSTS | $1,057,893 | |||
RECOMMENDED SAVINGS* | $1,082,321 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Fuel Oil #2 | Wood | Personnel Changes | Increase in Production | Electricity Usage | Electricity Demand | Electricity Fees | Fuel Oil #2 | Wood | Personnel Changes | Increase in Production | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | MMBtu | $ | $ | $ | % | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.3414 BURN WASTE TO PRODUCE STEAM TO DRIVE A STEAM TURBINE GENERATOR SET AND USE STEAM EXHAUST FOR HEAT |
Savings: $625,184 Cost: $1,387,500 |
$182,841 | 5,631,301 | $54,839 | 29,337 | - | - | $504,320 | 96,399 | $(-116,816) | (-128,427) | - | - | - | - |
$182,841 5,631,301 kWh |
$54,839 29,337 kW-months/year |
- - $ |
$504,320 96,399 MMBtu |
$(-116,816) (-128,427) MMBtu |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $2,377 Cost: $2,124 |
$2,377 | 47,186 | - | - | - | - | - | - | - | - | - | - | - | - |
$2,377 47,186 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - MMBtu |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.1311 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT |
Savings: $2,070 Cost: $4,700 |
$3,142 | 62,427 | $320 | 101 | - | - | $(-1,392) | (-266) | - | - | - | - | - | - |
$3,142 62,427 kWh |
$320 101 kW-months/year |
- - $ |
$(-1,392) (-266) MMBtu |
- - MMBtu |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.8123 PAY UTILITY BILLS ON TIME |
Savings: $1,617 Cost: - |
- | - | - | - | $1,617 | - | - | - | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$1,617 - $ |
- - MMBtu |
- - MMBtu |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $856 Cost: $890 |
- | - | - | - | - | - | $856 | 131 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$856 131 MMBtu |
- - MMBtu |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.2136 INSTALL / REPAIR INSULATION ON STEAM LINES |
Savings: $752 Cost: $490 |
- | - | - | - | - | - | $752 | 115 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$752 115 MMBtu |
- - MMBtu |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $666 Cost: $1,088 |
$518 | 10,258 | $148 | 47 | - | - | - | - | - | - | - | - | - | - |
$518 10,258 kWh |
$148 47 kW-months/year |
- - $ |
- - MMBtu |
- - MMBtu |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7134 USE PHOTOCELL CONTROLS |
Savings: $387 Cost: $600 |
$387 | 7,620 | - | - | - | - | - | - | - | - | - | - | - | - |
$387 7,620 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - MMBtu |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $375 Cost: $230 |
$375 | 7,620 | - | - | - | - | - | - | - | - | - | - | - | - |
$375 7,620 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - MMBtu |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $212 Cost: $518 |
$163 | 3,224 | $49 | 16 | - | - | - | - | - | - | - | - | - | - |
$163 3,224 kWh |
$49 16 kW-months/year |
- - $ |
- - MMBtu |
- - MMBtu |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 3.7212 IMPROVED MATERIAL HANDLING (MIXING AND TRANSFER) |
Savings: $8,450 Cost: $52,500 |
$7,036 | 139,801 | $1,414 | 448 | - | - | - | - | - | - | - | - | - | - |
$7,036 139,801 kWh |
$1,414 448 kW-months/year |
- - $ |
- - MMBtu |
- - MMBtu |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
12: 4.111 ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK |
Savings: $437,500 Cost: $784,300 |
- | (-115,768) | - | - | - | - | - | - | - | - | - | - | $437,500 | - |
- (-115,768) kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - MMBtu |
- - $ |
$437,500 - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
13: 4.513 RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE LABOR COSTS |
Savings: $1,875 Cost: $965 |
- | - | - | - | - | - | - | - | - | - | $1,875 | - | - | - |
- - kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - MMBtu |
$1,875 - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $1,082,321 Cost: $2,235,905 |
$196,839 | 5,793,669 | $56,770 | 29,949 | $1,617 | - | $504,536 | 96,379 | $(-116,816) | (-128,427) | $1,875 | - | $437,500 | - | $196,839 5,793,669 kWh |
$56,770 29,949 kW-months/year |
$1,617 - $ |
$504,536 96,379 MMBtu |
$(-116,816) (-128,427) MMBtu |
$1,875 - $ |
$437,500 - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - MMBtu |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | MMBtu | $ | $ | $ | % | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Fuel Oil #2 | Wood | Personnel Changes | Increase in Production | Electricity Usage | Electricity Demand | Electricity Fees | Fuel Oil #2 | Wood | Personnel Changes | Increase in Production |