Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Maine |
---|---|
Assessment Year | 2000 |
Principal Product | Dimensional lumber |
NAICS | n/a |
SIC | 2421 - Sawmills And Planing Mills, General |
Sales | $10,000,000-$50,000,000 |
# of Employees | 130 |
Plant Area (Sq.Ft.) | 57,220 |
Annual Production | 93,000 Thousand Feet |
Production Hrs. Annual | 4,000 |
Location (State) | ME |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $1,078,743 | 13,512,603 | kWh | $0.08 |
Electricity Demand | $233,884 | 29,485 | kW-months/year | $7.93 |
Electricity Fees | $(-259,329) | - | $ | - |
Fuel Oil #2 | $4,498 | 941 | MMBtu | $4.78 |
Wood | $967,526 | 403,136 | MMBtu | $2.40 |
TOTAL ENERGY COSTS | $2,025,322 | |||
RECOMMENDED SAVINGS* | $1,609,119 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Wood | Administrative Changes | Increase in Production | Electricity Usage | Electricity Demand | Electricity Fees | Wood | Administrative Changes | Increase in Production | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | $ | $ | % | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $252,792 Cost: $97,800 |
- | - | - | - | $252,792 | - | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$252,792 - $ |
- - MMBtu |
- - $ |
- - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $49,880 Cost: $44,850 |
$49,880 | 624,560 | - | - | - | - | - | - | - | - | - | - |
$49,880 624,560 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - $ |
- - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7134 USE PHOTOCELL CONTROLS |
Savings: $11,195 Cost: $4,080 |
$11,195 | 140,094 | - | - | - | - | - | - | - | - | - | - |
$11,195 140,094 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - $ |
- - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 3.6123 BURN WOOD BY-PRODUCTS FOR HEAT |
Savings: $631,036 Cost: $1,864,500 |
$740,424 | 12,595,252 | $96,049 | 16,978 | - | - | $(-167,332) | (-175,824) | $(-38,105) | - | - | - |
$740,424 12,595,252 kWh |
$96,049 16,978 kW-months/year |
- - $ |
$(-167,332) (-175,824) MMBtu |
$(-38,105) - $ |
- - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 3.1191 CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS |
Savings: $184,216 Cost: $324,000 |
- | - | - | - | - | - | $184,216 | 41,278 | - | - | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$184,216 41,278 MMBtu |
- - $ |
- - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 4.451 ADD ADDITIONAL PRODUCTION SHIFT |
Savings: $480,000 Cost: - |
- | - | - | - | - | - | - | - | - | - | $480,000 | - |
- - kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - $ |
$480,000 - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $1,609,119 Cost: $2,335,230 |
$801,499 | 13,359,906 | $96,049 | 16,978 | $252,792 | - | $16,884 | (-134,546) | $(-38,105) | - | $480,000 | - | $801,499 13,359,906 kWh |
$96,049 16,978 kW-months/year |
$252,792 - $ |
$16,884 (-134,546) MMBtu |
$(-38,105) - $ |
$480,000 - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - $ |
- - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | $ | $ | % | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Wood | Administrative Changes | Increase in Production | Electricity Usage | Electricity Demand | Electricity Fees | Wood | Administrative Changes | Increase in Production |