Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Maine |
---|---|
Assessment Year | 2000 |
Principal Product | Beer |
NAICS | n/a |
SIC | 2082 - Malt Beverages |
Sales | $1,000,000-$5,000,000 |
# of Employees | 20 |
Plant Area (Sq.Ft.) | 15,000 |
Annual Production | 15,000 BBL |
Production Hrs. Annual | 3,000 |
Location (State) | ME |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $16,082 | 213,951 | kWh | $0.08 |
Electricity Demand | $6,657 | 767 | kW-months/year | $8.68 |
Electricity Fees | $896 | - | $ | - |
Natural Gas | $9,934 | 1,509 | MMBtu | $6.58 |
TOTAL ENERGY COSTS | $39,358 | |||
RECOMMENDED SAVINGS* | $34,736 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $31,683 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Personnel Changes | Water Consumption | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Personnel Changes | Water Consumption | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | $ | $ | Tgal | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.1311 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT |
Savings: $1,601 Cost: $3,600 |
$1,083 | 14,361 | $781 | 90 | $(-263) | (-61) | - | - | - | - | - | - |
$1,083 14,361 kWh |
$781 90 kW-months/year |
$(-263) (-61) MMBtu |
- - Tgal |
- - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $1,300 Cost: $3,542 |
$1,146 | 15,240 | $154 | 18 | - | - | - | - | - | - | - | - |
$1,146 15,240 kWh |
$154 18 kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.2136 INSTALL / REPAIR INSULATION ON STEAM LINES |
Savings: $152 Cost: $384 |
- | - | - | - | $152 | 19 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$152 19 MMBtu |
- - Tgal |
- - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 3.4114 REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER |
Savings: $1,848 Cost: - |
$(-232) | (-3,517) | - | - | - | - | $1,495 | 280,819 | - | - | $585 | - |
$(-232) (-3,517) kWh |
- - kW-months/year |
- - MMBtu |
$1,495 280,819 Tgal |
- - $ |
$585 - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 4.513 RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE LABOR COSTS |
Savings: $29,835 Cost: $4,434 |
$(-113) | (-1,465) | $(-52) | (-6) | - | - | - | - | $30,000 | - | - | - |
$(-113) (-1,465) kWh |
$(-52) (-6) kW-months/year |
- - MMBtu |
- - Tgal |
$30,000 - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $34,736 Cost: $11,960 |
$1,884 | 24,619 | $883 | 102 | $(-111) | (-42) | $1,495 | 280,819 | $30,000 | - | $585 | - | $1,884 24,619 kWh |
$883 102 kW-months/year |
$(-111) (-42) MMBtu |
$1,495 280,819 Tgal |
$30,000 - $ |
$585 - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $31,683 Cost: $4,434 |
$(-345) | (-4,982) | $(-52) | (-6) | - | - | $1,495 | 280,819 | $30,000 | - | $585 | - | $(-345) (-4,982) kWh |
$(-52) (-6) kW-months/year |
- - MMBtu |
$1,495 280,819 Tgal |
$30,000 - $ |
$585 - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | $ | $ | Tgal | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Personnel Changes | Water Consumption | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Personnel Changes | Water Consumption |