Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Miami |
---|---|
Assessment Year | 2003 |
Principal Product | Pharmaceutical (Tablets & Capsules) |
NAICS | 325412 - Pharmaceutical Preparation Manufacturing |
SIC | 2834 - Pharmaceutical Preparations |
Sales | $50,000,000-$100,000,000 |
# of Employees | 264 |
Plant Area (Sq.Ft.) | 46,723 |
Annual Production | 375,000,000 Pieces |
Production Hrs. Annual | 0 |
Location (State) | FL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $379,222 | 8,071,978 | kWh | $0.05 |
Electricity Demand | $185,896 | 18,664 | kW-months/year | $9.96 |
Natural Gas | $190,445 | 31,170 | MMBtu | $6.11 |
TOTAL ENERGY COSTS | $1,005,563 | |||
RECOMMENDED SAVINGS* | $344,913 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $23,406 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Administrative Changes | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.8114 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE |
Savings: $17,331 Cost: $1,000 |
- | - | - | - | - | - | - | - | $17,331 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
$17,331 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE |
Savings: $10,356 Cost: $3,900 |
$10,356 | 147,943 | - | - | - | - | - | - | - | - |
$10,356 147,943 kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.2113 REPAIR OR REPLACE STEAM TRAPS |
Savings: $3,177 Cost: $1,160 |
- | - | - | - | $3,177 | 520 | - | - | - | - |
- - kWh |
- - kW-months/year |
$3,177 520 MMBtu |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $2,284 Cost: $441 |
$2,284 | 32,629 | - | - | - | - | - | - | - | - |
$2,284 32,629 kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $2,707 Cost: $6,341 |
$2,285 | 32,275 | $422 | 49 | - | - | - | - | - | - |
$2,285 32,275 kWh |
$422 49 kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7232 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL |
Savings: $7,443 Cost: $400,000 |
$7,443 | 106,329 | - | - | - | - | - | - | - | - |
$7,443 106,329 kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT |
Savings: $38,829 Cost: $70,000 |
- | - | - | - | $38,829 | 6,355 | - | - | - | - |
- - kWh |
- - kW-months/year |
$38,829 6,355 MMBtu |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 3.4155 METER WASTE WATER |
Savings: $12,786 Cost: $1,950 |
- | - | - | - | - | - | $12,786 | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$12,786 - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 3.6193 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS |
Savings: $250,000 Cost: $43,000 |
- | - | - | - | - | - | $250,000 | 1,841,000 | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$250,000 1,841,000 Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $344,913 Cost: $527,792 |
$22,368 | 319,176 | $422 | 49 | $42,006 | 6,875 | $262,786 | 1,841,000 | $17,331 | - | $22,368 319,176 kWh |
$422 49 kW-months/year |
$42,006 6,875 MMBtu |
$262,786 1,841,000 Tgal |
$17,331 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $23,406 Cost: $403,110 |
$7,443 | 106,329 | - | - | $3,177 | 520 | $12,786 | - | - | - | $7,443 106,329 kWh |
- - kW-months/year |
$3,177 520 MMBtu |
$12,786 - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Administrative Changes | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Administrative Changes |