Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
IAC Center | University of Miami |
---|---|
Assessment Year | 2006 |
Principal Product | Bakery Goods |
NAICS | 311812 - Commercial Bakeries |
SIC | 2051 - Bread, Cake, And Related Products |
Sales | $50,000,000-$100,000,000 |
# of Employees | 300 |
Plant Area (Sq.Ft.) | 230,000 |
Annual Production | 65,314,000 Pounds |
Production Hrs. Annual | 7,488 |
Location (State) | FL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $992,459 | 16,404,000 | kWh | $0.06 |
Electricity Demand | $199,701 | 33,963 | kW-months/year | $5.88 |
Electricity Fees | $204,266 | - | $ | - |
Natural Gas | $752,739 | 84,954 | MMBtu | $8.86 |
TOTAL ENERGY COSTS | $2,149,165 | |||
RECOMMENDED SAVINGS* | $249,241 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $144,930 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Usage | Electricity Demand | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $99,039 Cost: $135,000 |
$89,866 | 1,135,680 | $9,173 | 1,560 |
$89,866 1,135,680 kWh |
$9,173 1,560 kW-months/year |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $45,221 Cost: $10,000 |
$40,409 | 510,667 | $4,812 | 818 |
$40,409 510,667 kWh |
$4,812 818 kW-months/year |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7447 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS |
Savings: $45,075 Cost: $16,854 |
$40,911 | 517,009 | $4,164 | 708 |
$40,911 517,009 kWh |
$4,164 708 kW-months/year |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $35,182 Cost: $964 |
$30,838 | 389,716 | $4,344 | 739 |
$30,838 389,716 kWh |
$4,344 739 kW-months/year |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $14,015 Cost: $780 |
$12,683 | 153,730 | $1,332 | 227 |
$12,683 153,730 kWh |
$1,332 227 kW-months/year |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $10,709 Cost: $30 |
$8,716 | 110,145 | $1,993 | 338 |
$8,716 110,145 kWh |
$1,993 338 kW-months/year |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $249,241 Cost: $163,628 |
$223,423 | 2,816,947 | $25,818 | 4,390 | $223,423 2,816,947 kWh |
$25,818 4,390 kW-months/year |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $144,930 Cost: $135,994 |
$129,420 | 1,635,541 | $15,510 | 2,637 | $129,420 1,635,541 kWh |
$15,510 2,637 kW-months/year |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Usage | Electricity Demand |