IAC logo
IAC Assessment: MI0163
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: MI0163
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Miami
Assessment Year 2008
Principal Product X-Ray Scanners
NAICS 334511 - Search, Detection, Navigation, Guidance, Aeronautical, and Nautical System and Instrument Manufactur
SIC 3812 - Search And Navigation Equipment
Sales $10,000,000-$50,000,000
# of Employees 300
Plant Area (Sq.Ft.) 130,000
Annual Production 400 Units
Production Hrs. Annual 2,080
Location (State) FL
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $250,235 2,966,700 kWh $0.08
Electricity Demand $12,308 8,267 kW-months/year $1.49
Electricity Fees $48,571 - $ -
TOTAL ENERGY COSTS $311,114
RECOMMENDED SAVINGS* $619,949 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $609,715
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Administrative Changes Electricity Usage Electricity Demand Administrative Changes
$ kWh $ kW-months/year $ $
01: 2.7496 INSTALL PARTITIONS TO REDUCE SIZE OF CONDITIONED SPACE Savings:
$600,000
Cost:
$200,000
$42,142 415,480 $5,119 1,512 $552,739 - $42,142
415,480
kWh
$5,119
1,512
kW-months/year
$552,739
-
$
02: 2.7425 CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD Savings:
$10,234
Cost:
$48,055
$8,411 73,883 $1,823 426 - - $8,411
73,883
kWh
$1,823
426
kW-months/year
-
-
$
03: 2.2511 INSULATE BARE EQUIPMENT Savings:
$4,023
Cost:
$1,957
$3,405 36,150 $618 178 - - $3,405
36,150
kWh
$618
178
kW-months/year
-
-
$
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$3,724
Cost:
$11,286
$3,061 32,498 $663 191 - - $3,061
32,498
kWh
$663
191
kW-months/year
-
-
$
05: 2.7447 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS Savings:
$1,968
Cost:
$2,151
$1,774 18,830 $194 56 - - $1,774
18,830
kWh
$194
56
kW-months/year
-
-
$
TOTAL RECOMMENDED Savings:
$619,949
Cost:
$263,449
$58,793 576,841 $8,417 2,363 $552,739 - $58,793
576,841
kWh
$8,417
2,363
kW-months/year
$552,739
-
$
TOTAL IMPLEMENTED Savings:
$609,715
Cost:
$215,394
$50,382 502,958 $6,594 1,937 $552,739 - $50,382
502,958
kWh
$6,594
1,937
kW-months/year
$552,739
-
$
Savings
Cost
$ kWh $ kW-months/year $ $
Electricity Usage Electricity Demand Administrative Changes Electricity Usage Electricity Demand Administrative Changes