Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Miami
Assessment Year 2009
Principal Product Windows & Doors
NAICS 327215 - Glass Product Manufacturing Made of Purchased Glass
SIC 3231 - Products Of Purchased Glass
Sales $10,000,000-$50,000,000
# of Employees 200
Plant Area (Sq.Ft.) 100,000
Annual Production 100,000 Pieces
Production Hrs. Annual 2,167
Location (State) PR
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $368,489 2,267,100 kWh $0.16
Electricity Demand $157,286 18,759 kW-months/year $8.38
Electricity Fees $5,400 - $ -
TOTAL ENERGY COSTS $531,175
RECOMMENDED SAVINGS* $108,344 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $32,420
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Electricity Usage Electricity Demand
$ kWh $ kW-months/year
01: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$41,487
Cost:
$31,140
$32,294 198,123 $9,193 1,097 $32,294
198,123
kWh
$9,193
1,097
kW-months/year
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$30,203
Cost:
$31,350
$23,390 143,901 $6,813 813 $23,390
143,901
kWh
$6,813
813
kW-months/year
03: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE Savings:
$23,952
Cost:
$3,320
$18,424 113,355 $5,528 627 $18,424
113,355
kWh
$5,528
627
kW-months/year
04: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$6,351
Cost:
$1,210
$4,943 30,325 $1,408 168 $4,943
30,325
kWh
$1,408
168
kW-months/year
05: 2.4323 USE OPTIMUM SIZE AND CAPACITY EQUIPMENT Savings:
$4,234
Cost:
$4,531
$3,295 20,217 $939 112 $3,295
20,217
kWh
$939
112
kW-months/year
06: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED Savings:
$2,117
Cost:
$40
$1,648 10,108 $469 56 $1,648
10,108
kWh
$469
56
kW-months/year
TOTAL RECOMMENDED Savings:
$108,344
Cost:
$71,591
$83,994 516,029 $24,350 2,873 $83,994
516,029
kWh
$24,350
2,873
kW-months/year
TOTAL IMPLEMENTED Savings:
$32,420
Cost:
$4,570
$25,015 153,788 $7,405 851 $25,015
153,788
kWh
$7,405
851
kW-months/year
Savings
Cost
$ kWh $ kW-months/year
Electricity Usage Electricity Demand Electricity Usage Electricity Demand